Abstract
Cross-field MRI translation is challenged by scarce paired
acquisitions and field-dependent changes in intensity and spatial-
frequency characteristics. We present an anatomy-anchored empirical
domain randomization framework for T1-weighted translation from
0.1T/1.5T/3T/5T to 7T in MRIxFields2026. Real 5T volumes provide
a shared anatomical anchor, while unpaired target-field cases define
case-coupled intensity quantiles and frequency statistics. Real-data di-
rectional spectra motivate an anisotropic effective image-domain MTF:
a positive-PSF radial attenuation profile is deformed ellipsoidally using
LR/AP/SI spectral scales and followed by re-projection to the same
target CDF. The resulting aligned pseudo-pairs train a single-channel
2D Restormer using only L1 loss. On the official hidden-set evaluation,
the full anisotropic model achieved Dice 0.901, LPIPS 0.104, SSIM 0.899,
Volume 0.915, and nRMSE 0.262.
Links to Paper and Supplementary Materials
Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026-sat/paper/MRIxFields2026_025.pdf
SharedIt Link: Not yet available
SpringerLink (DOI): Not yet available
Supplementary Material: Not Submitted
Link to Open Review
Open Review Page: https://openreview.net/forum?id=XU7MUcGNGT
BibTex
@InProceedings{WuYan_AnatomyAnchored_MICCAISAT2026,
author = { Wu, Yang AND Sun, Tianyang AND Chen, Yi AND Song, Haiyu AND Shi, Feng AND Wang, Qian},
title = { { Anatomy-Anchored Empirical Domain Randomization for Cross-Field T1-Weighted MRI Translation } },
booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026 Workshops and Challenges},
year = {2026},
publisher = {Springer Nature Switzerland},
volume = {LNCS 17274},
month = {pending},
page = {pending}
}