Abstract

Ultra-low-field(0.1T)MRIexpandspoint-of-careneuroimag- ing but suffers from low SNR and reduced tissue contrast. Task 2 of the MRIxFields2026 challenge requires synthesizing high-field equivalents (1.5 T, 3 T, 5 T, 7 T) across three contrasts (T1W, T2W, T2FLAIR), under a 2 × 24 GB GPU budget and a validation split with no evaluable pairs. A calibrated similarity test confirms that all 15 released volumes are distinct subjects (Cohen’s d = 3.45 for brain-mask Dice and 1.84 for normalized mutual information), necessitating a pairing-independent regime: synthetic supervision from physically degraded high-field vol- umes,followedbydomainadaptationthatanchorsreconstructiononsyn- thetic pairs while enforcing structural consistency against real 0.1 T data through MIND, a contrast-invariant descriptor, using a 2.5D NAFNet backbone. A controlled ablation reveals that most adaptation gains trace to extra training time rather than the MIND term, which adds a small but consistent increment once real-data exposure is controlled. On syn- thetic validation, the 12 models achieve SSIM 0.898–0.956 and nRMSE 0.034–0.063, with domain adaptation improving SSIM in 11 of 12 com- binations and nRMSE in all 12 cases at a minor T1W-specific LPIPS cost. Server-side evaluation confirms a substantial synth-to-real gap. A chain of five checks demonstrates that the persistent T2FLAIR deficit is a genuine contrast-synthesis failure rather than a segmentation artifact. Finally, a revised pipeline (full-subject training, longer schedule) scored 0.7994 versus 0.8060 for our original submission. This small, unpredicted regression underscores that ground-truth-free local proxies cannot fully substitute for real-data evaluation.

Links to Paper and Supplementary Materials

Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026-sat/paper/MRIxFields2026_023.pdf

SharedIt Link: Not yet available

SpringerLink (DOI): Not yet available

Supplementary Material: https://papers.miccai.org/miccai-2026-sat/supp/MRIxFields2026_023_supp.pdf

Link to Open Review

Open Review Page: https://openreview.net/forum?id=rpGEW3rkDk

BibTex

@InProceedings{CisJua_PairingIndependent_MICCAISAT2026,
        author = { Cisneros Jacome, Juan Andres AND Zea Monsalve, Lisset Andrea AND Garcia Mosquera, Laura Valentina AND Torres Torres, Luis Fernando},
        title = { { Pairing-Independent Cross-Field MRI Translation: Synthetic Supervision and Structure-Preserving Domain Adaptation for Ultra-Low-Field to High-Field Synthesis } },
        booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026 Workshops and Challenges},
        year = {2026},
        publisher = {Springer Nature Switzerland},
        volume = {LNCS 17274},
        month = {pending},
        page = {pending}
}


back to top