Abstract

Abdominal ultrasound is indispensable for rapid, noninvasive trauma triage. However, interpreting the subtle dynamic cues embedded in continuous scanning is time-intensive and operator-dependent. Parameter-Efficient Image-to-Video Transfer Learning (PEIVTL), which efficiently adapts pre-trained image models to the video domain, notably through visual-textual alignment, offers a promising paradigm for ultrasound video analysis. Nevertheless, substantial spatiotemporal and semantic variations arising from physician-dependent scanning practices continue to limit the effectiveness and generalizability of this framework. We propose TRUST, a scan-aware PEIVTL framework that explicitly models fine-grained spatiotemporal variations to enable reliable ultrasound video understanding. First, we introduce a Cross-Frequency Collaborative Adapter (CFCA) that establishes mutual constraints between low- and high-frequency components, enhancing discriminative spatial feature extraction under heavy speckle corruption. Second, we design a Multi-Granularity Motion-Aware (MGMA) module that integrates local temporal convolutions with motion-prior-guided global self-attention, jointly capturing stable intra-view patterns and abrupt inter-view transitions to characterize complex scanning dynamics. Third, a Visual Query Semantic Aggregation (VQSA) module dynamically generates text prototypes conditioned on visual features, enabling adaptive visual-textual alignment robust to intra-class variability under diverse scanning conditions. Experiments on in-house ultrasound trauma datasets demonstrate that TRUST outperforms state-of-the-art methods by 9.63% with superior computational efficiency.

Links to Paper and Supplementary Materials

Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026/paper/0922_paper.pdf

SharedIt Link: Not yet available

SpringerLink (DOI): Not yet available

Supplementary Material: Not Submitted

Link to the Code Repository

N/A

Link to the Dataset(s)

N/A

BibTex

@InProceedings{WanEng_TRUST_MICCAI2026,
        author = { Wang, Enguang AND Zhou, Hao AND Gao, Shuo AND Liu, Tuo AND Zhou, Guangquan},
        title = { { TRUST: Efficient Abdominal Trauma Recognition via Image-to-Ultrasound-Video Transfer Learning } },
        booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026},
        year = {2026},
        publisher = {Springer Nature Switzerland},
        volume = {LNCS 16879},
        month = {September},
        page = {pending}
}


Reviews

Review #1

  • Please describe the contribution of the paper

    This paper presents the pioneering application of PEIVTL to abdominal ultrasound video analysis. By developing a scan-aware framework, it explicitly models fine-grained spatiotemporal dynamics, ensuring robust and reliable ultrasound video understanding.

  • Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.

    1.Compared to conventional wavelet-based frequency enhancement methods, this paper proposes CFCA (Constrained Frequency Component Alignment), which explicitly models the interactive constraints between low-frequency and high-frequency components. By utilizing a spatial mask generated from low-frequency sub-bands to provide gated guidance for high-frequency features, this mechanism effectively suppresses imaging noise while precisely preserving critical clinical diagnostic details. 2.Addressing continuous view sequences in ultrasound scanning, this work employs a dual-branch architecture to distinguish between smooth scanning views and discontinuous views caused by probe repositioning. By incorporating a motion prior to reinforce local spatiotemporal continuity and deeply integrating motion representations from both branches, the approach effectively eliminates transient noise interference at view-switching boundaries. 3.Integrating LLM-generated clinical descriptions validated by human experts, this paper leverages a cross-modal attention mechanism to achieve a deep fusion of real-time visual embeddings and a dynamic textual knowledge base. This facilitates a paradigm shift from “global-level category alignment” to “instance-level semantic alignment. “ Visualization analysis of experimental results demonstrates that, compared to baseline models, our method more accurately captures the semantic associations between anatomical structures and pathological features.

  • Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.

    1.The figures in the manuscript suffer from low resolution, and the inclusion of equations as raster images further compromises visual clarity. Additionally, inconsistencies in variable naming and formatting within the Methodology section detract from the overall readability and technical rigor of the paper. 2.Regarding the clinical descriptions generated by the LLM, further clarification is required on the standardization of the prompting strategy. Moreover, the specific clinical criteria or medical guidelines employed during the human verification process should be explicitly detailed to ensure the reliability of the knowledge base. 3.While the proposed method addresses several technical challenges, the primary clinical objective remains underspecified. There is a lack of alignment between the “ultrasound video analysis” mentioned in the abstract, the “optimization of classification accuracy” in the methodology, and the “normal/abnormal” labels in the dataset. It is essential to clarify the clinical utility: is this system intended as a screening tool to support physician judgment, or as a computer-aided diagnosis (CAD) system for direct diagnostic support? The clinical significance needs to be more robustly articulated.

  • Please rate the clarity and organization of this paper

    Satisfactory

  • Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.

    The submission does not provide sufficient information for reproducibility.

  • Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?

    N/A

  • Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html

    N/A

  • Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.

    (4) Weak Accept — marginally above the acceptance threshold, but would not mind if rejected, dependent on rebuttal

  • Please justify your recommendation. What were the major factors that led you to your overall score for this paper?

    1.Significant technical contribution: This paper applies PEIVTL to abdominal ultrasound for the first time, and proposes CFCA module and dual-branch motion prior architecture. These designs accurately capture the pain points of “high noise” and “discontinuities caused by probe movement” in ultrasound imaging. The use of LLM to build a dynamic knowledge base and achieve “instance-level semantic alignment” is leading in the technology paradigm. 2.Key bug: blurry images, unvectorized formulas, and inconsistent variable naming, which directly degrade readability. The clinical purpose is not clear. The lack of a coherent logical closed loop between abstract, method, and dataset annotations (normal/abnormal) makes the practical application of this technique questionable. Although the algorithm is described, there is a lack of detail on the basis of Prompt standardization and manual validation, and no information on code or adequate reproduction is provided at this time.

  • Reviewer confidence

    Very confident (4)

  • [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.

    Accept

  • [Post rebuttal] Please justify your final decision from above.

    The authors’ rebuttal adequately addresses all reviewer concerns regarding clinical task definition, methodological novelty, text knowledge construction, dataset limitations and experimental settings. The proposed TRUST model shows solid clinical motivation and technical rationality for abdominal trauma ultrasound video grounding.



Review #2

  • Please describe the contribution of the paper

    This paper proposes TRUST, a scan-aware parameter-efficient image-to-video transfer learning framework for abdominal ultrasound trauma recognition. Built upon a CLIP-style paradigm, the method integrates three key modules: a cross-frequency adapter for spatial feature enhancement, a motion-aware temporal modeling module, and a dynamic visual-text alignment mechanism.

  • Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.

    1.The paper addresses an important and practical problem in ultrasound video analysis, particularly in trauma triage scenarios where temporal dynamics are critical. 2.The proposed framework is well-structured, and the design of CFCA, MGMA, and VQSA is reasonably motivated from spatial, temporal, and semantic perspectives. 3.Empirical results show clear improvements over several recent PEIVTL baselines, with consistent gains across metrics.

  • Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.

    1.The dataset is very limited (only 294 videos) and private, which raises concerns about generalization and robustness. The absence of evaluation on public benchmarks significantly weakens the claims. 2.The technical novelty is incremental. Most components (frequency modeling, temporal aggregation, and cross-modal alignment) are adaptations or combinations of existing ideas rather than fundamentally new contributions. 3.The comparison is somewhat insufficient. While PEIVTL baselines are included, stronger or more diverse baselines (e.g., fully supervised video models or alternative temporal architectures) are missing. 4.The reliance on CLIP-style frozen encoders limits the exploration of representation learning itself, making the contribution more engineering-oriented than algorithmically novel.

  • Please rate the clarity and organization of this paper

    Satisfactory

  • Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.

    The submission does not mention open access to source code or data, but provides a clear and detailed description of the algorithm to ensure reproducibility.

  • Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?

    N/A

  • Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html

    N/A

  • Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.

    (2) Reject — should be rejected, independent of rebuttal

  • Please justify your recommendation. What were the major factors that led you to your overall score for this paper?

    While the paper is well-written and presents a reasonably effective framework, the overall contribution is not strong enough for a top-tier venue. The limited dataset, lack of strong generalization evidence, and incremental nature of the technical contributions make it difficult to justify acceptance.

  • Reviewer confidence

    Very confident (4)

  • [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.

    Reject

  • [Post rebuttal] Please justify your final decision from above.

    The rebuttal clarifies several aspects of the task formulation, text-bank construction, and the motivation for using PEIVTL with frozen encoders. However, my major concerns remain insufficiently resolved. The evaluation is still limited to a single private dataset with only 294 videos and no external, multi-center, multi-device, or public benchmark validation. The proposed modules are reasonable but largely represent an engineering integration of existing ideas, including frequency-domain enhancement, temporal aggregation, and CLIP-style visual-text alignment. In addition, the comparison remains restricted to PEIVTL baselines, without stronger fully supervised or lightweight temporal video models. Therefore, although I acknowledge the clinical relevance and the authors’ effort in the rebuttal, I do not think the current evidence is sufficient for MICCAI acceptance.



Review #3

  • Please describe the contribution of the paper

    This paper focuses on the recognition of abdominal trauma ultrasound videos. Based on a CLIP-style image-to-video transfer learning framework, it proposes the TRUST method. The approach mainly consists of three components: the Cross-Frequency Collaborative Adapter (CFCA) module for enhancing spatial representation in ultrasound speckle scenarios, the Multi-Granularity Motion-Aware (MGMA) module for modeling short-term continuous movements and long-range scanning variations, and the Visual-Query Semantic Aggregation (VQSA) module that dynamically aggregates text prototypes according to visual features. By combining these three designs, the authors aim to jointly boost spatiotemporal modeling and cross-modal alignment capabilities in abdominal ultrasound videos, achieving performance superior to multiple PEIVTL baselines on a self-built dataset.

  • Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.

    The research topic possesses certain clinical significance, as abdominal trauma ultrasound video analysis is inherently a practical and challenging problem; the paper presents a complete overall narrative by designing modules from the perspectives of spatial modeling, temporal modeling, and vision-text alignment with coherent logical reasoning; extensive comparisons are conducted with a variety of image-to-video transfer learning and video-CLIP methods, and the experimental results demonstrate obvious performance improvements; comprehensive ablation experiments are also provided to verify the incremental contributions of each module; even for readers who are not experts in this specific research direction, the overall methodology and workflow of this paper are easy to follow and understand.

  • Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.

    From my perspective, the proposed method appears to be a combination of existing mainstream ideas with solid overall engineering implementation, yet the core methodological innovations lack sufficient refinement and concentration; the dataset is self-constructed by the authors with only 294 videos, which is relatively limited in scale, and evaluations are conducted merely on a single private dataset, resulting in insufficient convincing evidence for generalization ability; the demonstration of whether the motion-prior position encoding truly conforms to practical scanning logic is inadequate, and it currently serves more as a reasonable surrogate rather than a strictly validated physical quantity; the vision-text branch relies on constructing and aggregating multiple textual descriptions for each category, and although this design is reasonable, I still have reservations regarding the text construction process, its sensitivity to experimental results, and the reproducibility issues caused by manual verification; my research background focuses more on natural images and general computer vision instead of ultrasound video analysis, so I have limited confidence in judging the sufficiency of relevant literature coverage in this specialized field and whether the performance gain reaches the state-of-the-art level for this specific task.

  • Please rate the clarity and organization of this paper

    Satisfactory

  • Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.

    The submission does not mention open access to source code or data, but provides a clear and detailed description of the algorithm to ensure reproducibility.

  • Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?

    N/A

  • Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html

    N/A

  • Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.

    (3) Weak Reject — marginally below the acceptance threshold, but would not mind if accepted, dependent on rebuttal

  • Please justify your recommendation. What were the major factors that led you to your overall score for this paper?

    I hereby issue a Weak Reject. The problem addressed in this paper is meaningful, the method design is relatively complete, and the experimental results outperform multiple relevant baselines, indicating that the authors have conducted solid and adequate work. Nevertheless, in my opinion, the main contributions of this paper lie primarily in integrating multiple well‑designed modules into a unified framework for abdominal ultrasound video recognition, rather than presenting a distinct and groundbreaking methodological innovation. In addition, all experiments are mainly conducted on a small-scale private dataset, leading to limited evidence regarding generalization and robustness. As my research expertise focuses on natural images and general vision rather than this specialized subfield, my evaluation will remain relatively conservative. Overall, this manuscript exhibits decent quality but is currently slightly below my acceptance threshold. However, I am not an expert in this field, so the reference value of my opinion can be reduced.

  • Reviewer confidence

    Not confident (1)

  • [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.

    N/A

  • [Post rebuttal] Please justify your final decision from above.

    N/A



Author Feedback

We thank the reviewers and meta-reviewer for recognizing the clinical significance of abdominal ultrasound video analysis, the coherent design of TRUST, and its clear improvements over relevant PEIVTL baselines. We summarize our response into five points. 1.{R1, Meta} Clinical task formulation. TRUST is a temporally grounded decision-support tool for rapid abdominal trauma screening, localizing start–end intervals of key segments in ultrasound videos. These intervals enable efficient clinical review and verification. Accordingly, dense frame-level annotations are used to supervise temporal localization and support video grounding, while also providing fine-grained supervision for adapting image-level pretrained representations to continuous ultrasound videos. The Jaccard index (tIoU) is adopted as the primary metric for its direct alignment with interval localization, while the other four metrics, such as accuracy, are reported as auxiliary measures of fine-grained recognition. 2.{R2, R3, Meta} Clinically motivated methodological novelty. TRUST is specifically designed for ultrasound temporal grounding in abdominal trauma screening, representing a novel application of PEIVTL to ultrasound video analysis. It addresses the spatiotemporal challenges of US videos: global temporal modeling under free-hand scanning dynamics and fine-grained spatial perception. MGMA forms the core of the video analysis framework by leveraging semantic changes between adjacent frames as a proxy for probe-induced variations, thereby preserving temporal continuity during stable scanning and preventing the fusion of unrelated anatomical views during transitions. Building on this, CFCA enhances frame-level discrimination for video grounding through cross-frequency collaborative learning, where low-frequency anatomical structures guide the selection of high-frequency details, while high-frequency cues preserve subtle abnormalities. Furthermore, VQSA replaces fixed category-level text prototypes with visually conditioned text aggregation, enabling clinical descriptions to align with the content of each scanning sequence dynamically. 3.{R1, R3, Meta} Text knowledge construction and verification. To ensure experimental fairness and clinical consistency, we employ a structured, slot-based prompting strategy with a fixed text bank finalized before training. The core template includes five clinical slots: [Category], [Modality], [Region], [Attribute], and [Temporal Context]. For each category, we extracted over 30 candidate sentences describing anatomy, echogenicity, and temporal dynamics. Experts then filtered them according to FAST principles to eliminate ambiguity and redundancy, forming the final fixed text bank. 4.{R2, R3} Dataset limitation and generalization. Ultrasound video analysis is a promising research direction, but large-scale, high-quality retrospective datasets remain limited because videos were not routinely recorded or systematically archived in historical workflows. Abdominal trauma data are further difficult to collect due to low case incidence and the time-critical nature of emergency scanning. Despite these challenges, we prospectively assembled 294 videos over three years under institutional ethical approval, and will continue expanding the cohort. 5.{R1, R2, Meta} Clarity, baselines, frozen encoders. 1) We will improve figure resolution, replace rasterized equations with vectorized formulas, and unify notation/formatting. 2) Given limited clinical video data, we adopt the PEIVTL setting with selected baselines and frozen encoders, rather than fully optimized temporal models (e.g., TCN, TimeSformer), which are more prone to overfitting in this regime. Accordingly, we compare representative methods within this paradigm, including unimodal PEIVTL and multimodal CLIP-based adaptations. Frozen encoders retain general visual–semantic representations, while lightweight module adaptation introduces ultrasound-specific priors.




Meta-Review

Meta-review #1

  • Your recommendation

    Invite for Rebuttal

  • Please justify your decision. In case you deviate from the reviewers’ recommendations, explain in detail the reasons why. In case of an invitation for rebuttal, clarify which points are important to address in the rebuttal.

    The reviewers generally agree that this work addresses a clinically meaningful problem in ultrasound video analysis and presents a technically sound framework with clear empirical improvements over relevant baselines. The overall framework is viewed as coherent and reasonably well designed.

    At the same time, the reviewers raised several concerns that are important to address in the rebuttal. The rebuttal should aim to address the following points, including but not limited to:

    1.The methodological novelty should be better justified, particularly whether the contribution goes beyond integrating existing ideas in frequency modeling, temporal aggregation, and cross-modal alignment into an engineering framework.

    2.The clinical goal of the system should be clarified more explicitly, including whether it is intended for screening, decision support, or direct computer-aided diagnosis, and how this aligns with the dataset labels and evaluation setting.

    3.Several designs require further clarification, e.g., standardization of the prompting strategy and the human verification process.

    4.The manuscript would benefit from improved methodological clarity, including notation consistency, clearer explanation of the knowledge construction pipeline.

  • After you have reviewed the rebuttal and updated reviews, please provide your recommendation based on all reviews and the authors’ rebuttal.

    Reject

  • Please justify your recommendation.

    While the paper addresses an important clinical problem and presents a reasonably complete framework, the rebuttal did not fully resolve the major concerns raised by the reviewers. In particular, questions remain regarding the methodological novelty, the support for some core design choices, and whether the current evidence is sufficient for acceptance. Therefore, my recommendation is Reject.



Meta-review #2

  • After you have reviewed the rebuttal and updated reviews, please provide your recommendation based on all reviews and the authors’ rebuttal.

    Reject

  • Please justify your recommendation.

    After rebuttal, the reviewers maintain the concerns on limited evaluation on a single small private dataset without external validation, the perception of the method as merely an engineering integration of existing ideas, and insufficient comparisons against stronger baselines.



Meta-review #3

  • After you have reviewed the rebuttal and updated reviews, please provide your recommendation based on all reviews and the authors’ rebuttal.

    Accept

  • Please justify your recommendation.

    The rebuttal addressed the main concerns pointed out during the review phase. The paper has sufficient novelty and discusses an intriguing topic that is of interest to the community.



back to top