Abstract

Deploying foundation models (FMs) in clinical imaging is limited by expert annotation cost and the opacity of API-served models that preclude gradient-based adaptation. Existing methods address these constraints separately: black-box prompt tuning assumes fixed labels, while active learning often requires gradients, internal features, logits, or calibrated probabilities. We present Prompt and Probe (P$^2$), a query-only framework for adapting frozen FMs to classification and segmentation while selecting informative unlabeled samples. A lightweight Visual Prompt Decoder (VIPD) maps shared semantic and anatomical embeddings to input-space prompts: global additive prompts for classification and spatial channel-concatenated prompts for segmentation, trained via zeroth-order optimization. For acquisition, the trained decoder probes unlabeled images with multi-scale perturbations; prompt and prediction shifts are summarized as image- and pixel-level instability scores and fused after per-batch normalization. Across seven public datasets, eight benchmarks, and six clinical modalities, P$^2$ reduces labeling by $40$–$60\%$ while outperforming black-box active learning baselines, achieving $91.8\%$ AUROC on CheXpert with $50\%$ labels and $58.5\%$ Dice on Kvasir-Seg with $10\%$ labels. Boundary instability from model-predicted masks, without segmentation ground truth, improves classification acquisition by up to 24.5 AUROC points, suggesting that joint spatial–semantic probing identifies anatomically ambiguous samples missed by task-specific selection.

Links to Paper and Supplementary Materials

Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026/paper/5623_paper.pdf

SharedIt Link: Not yet available

SpringerLink (DOI): Not yet available

Supplementary Material: Not Submitted

Link to the Code Repository

N/A

Link to the Dataset(s)

N/A

BibTex

@InProceedings{MahDwa_Prompt_MICCAI2026,
        author = { Mahapatra, Dwarikanath AND Das, Abhijit AND Roy, Sudipta AND Pandey, Manish AND Dhar, Joy AND Zaidi, Nayyar AND Ge, Zongyuan AND Bozorgtabar, Behzad AND Reyes, Mauricio AND Razzak, Imran},
        title = { { Prompt and Probe: Data-Efficient Adaptation of Black-Box Foundation Models via Unified Active Visual Prompting } },
        booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026},
        year = {2026},
        publisher = {Springer Nature Switzerland},
        volume = {LNCS 16879},
        month = {September},
        page = {pending}
}


Reviews

Review #1

  • Please describe the contribution of the paper

    The authors propose P^2, a framework that simultaneously addresses two constraints in deploying medical foundation models: (i) lack of gradient access in API-served FMs, and (ii) annotation scarcity.

    Key contributions: 1.Unified VIPD producing both global and spatial prompts from a shared backbone under zeroth-order optimization.

    2.Multi-scale instability-driven acquisition that quantifies image- and pixel-level prediction shifts, fused via a single γ-weighted ranking.

    3.Dynamically weighted cross-task loss combining supervised and three unsupervised regularizers.

    4.Spatial signals improve classification AUROC by up to 24.5 points, claimed evidence that task-unified selection is “fundamentally superior” to task-specific.

  • Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.

    1.The problem statement is genuinely novel and practically motivated. The compound constraint — black-box FMs and annotation budget — is a real gap.

    2.Using a shared backbone with two heads is parameter-efficient, important under SPSA where each parameter incurs query cost. The choice of ~2.1M parameters is reasonably small for zeroth-order optimization.

    3.The evaluation is rigorous with seven datasets across six modalities, three task settings (C, S, joint), and 10-run statistical reporting.

    4.Interesting results from the cross-task transfer which shows that spatial uncertainty is a useful signal for classification AL.

    5.The query budget (with ~50k queries at 1k queries/min) is practical and clinically useful as a deployment metric.

  • Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.

    1.Removing a single weighting term (w_b=0) causing a 24.5 AUROC drop on a classification-only dataset (CheXpert) is extraordinarily large. This needs more explanation given that rhe boundary disagreement signal I_bnd is computed on segmentation masks. CheXpert has no segmentation ground truth. Moreover, the mechanism by which a segmentation signal produces this magnitude of classification gain on a chest X-ray classification task is not explained.

    2.L_unified is presented without weighting coefficients between L_task, L_div, L_ent, L_feat, and without explaining the balancing mechanism.

    3.Refering to Fig. 3, the FSL is reported as 92.4%. However, state-of-the-art CheXpert AUROC values for the standard 5-finding evaluation are typically 0.92–0.94.Why is the FSL ceiling so low ? My guess is a weak implementation (ex. : a DenseNet121-baseline compared to a ViT-B/16 + foundation model for P^2).

    4.The paper provides no description of the hyper-parameter tuning protocol (held-out validation set? cross-validation? grid search budget?).

    5.The authors claim that task-unified is “fundamentally” superior given the evidence is that adding spatial signals helps classification on medical imaging benchmarks where anatomical structure correlates with diagnosis. However, this does not seem to generalize to pure classification tasks where no segmentation prior exists. The term “fundamental” appears to be the misnomer. It would be great if the authors can clarify this.

  • Please rate the clarity and organization of this paper

    Good

  • Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.

    The submission has provided an anonymized link to the source code, dataset, or any other dependencies.

  • Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?

    N/A

  • Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html
    1. The Statistical claim “All p<0.01” is reported globally without stating what test, what comparison, how multiple-comparison correction was handled.

    2.Table 2 appears inconsistent. ACDC under “Ours” shows AUC . 887 / Dice . 865, but the “Equal” column (α₁=0.5, γ=0.5) shows . 882/. 875 — yet “Ours” for ACDC also uses α₁=0.5, γ=0.5 per Table 1.Shouldn’t the two be identical ?

    3.Fig. 4 references appear broken (“Fig. ??” in Section 3 protocol description- “already subsumed by our w/o Probe ablation).

    4.Reference [3] is given as anonymous even though it is out in the AAAI proceedings. Please revise this.

  • Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.

    (3) Weak Reject — marginally below the acceptance threshold, but would not mind if accepted, dependent on rebuttal

  • Please justify your recommendation. What were the major factors that led you to your overall score for this paper?

    The paper tackles a genuine and important problem with a reasonable architectural design. The core ideas are sound and the empirical breadth is real. However, some claims in the paper need to be substantiated further: numerical result tables, clarification of L_unified weighting, hyperparameter selection protocol, and a control for the spatial-signal-helps-classification finding.

  • Reviewer confidence

    Very confident (4)

  • [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.

    Accept

  • [Post rebuttal] Please justify your final decision from above.

    The rebuttal provided by the authors answers most of the questions raised in the review. The changes proposed are addition of certain metrics and revising certain sentences in the paper to improve clarity which is fine. I am therefore revising my rating to weak accept (4).



Review #2

  • Please describe the contribution of the paper

    The paper proposes Prompt and Probe, a unified framework that addresses both annotation cost and the lack of gradient access in API-served foundation models. It introduces a Visual Prompt Decoder trained via zeroth-order optimization, and leverages it for active learning through multi-scale perturbation-based probing with a unified acquisition strategy across classification and segmentation tasks, achieving improved label efficiency and performance.

  • Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.

    The paper proposes a novel Prompt and Probe (P2) framework along with a lightweight Visual Prompt Decoder to address the dual challenges of deploying foundation models in clinical imaging. Extensive experiments on seven public datasets covering six clinical modalities demonstrate that P2 reduces labeling requirements by 40–60% while matching or exceeding fully supervised baselines.

  • Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.

    1 The paper lacks clear organization, and the writing is difficult to follow. 2 There is insufficient explanation of certain design choices, such as why addition is used in the classification branch while concatenation is used in the segmentation branch. 3 It is unclear whether Ltask and other loss functions are defined under the same scale; if not, the absence of balancing coefficients may be an issue.

  • Please rate the clarity and organization of this paper

    Satisfactory

  • Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.

    The submission has provided an anonymized link to the source code, dataset, or any other dependencies.

  • Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?

    N/A

  • Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html

    N/A

  • Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.

    (5) Accept — should be accepted, independent of rebuttal

  • Please justify your recommendation. What were the major factors that led you to your overall score for this paper?

    The authors propose a novel Prompt and Probe framework, and through extensive experiments on seven public datasets across six clinical modalities, demonstrate that it reduces labeling requirements by 40–60% while achieving performance comparable to or better than fully supervised baselines.

  • Reviewer confidence

    Somewhat confident (2)

  • [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.

    Accept

  • [Post rebuttal] Please justify your final decision from above.

    The authors’ rebuttal has fully addressed my previous questions, and this paper meets the acceptance standards of MICCAI.



Review #3

  • Please describe the contribution of the paper

    This paper proposes Prompt and Probe (P²), a unified framework for adapting frozen, API-served foundation models (FMs) to both classification and segmentation in clinical imaging, while simultaneously performing annotation-efficient active learning—all using only input–output queries with no access to model weights, gradients, or internal representations.The framework operates in two stages. In the Prompt stage, a lightweight Visual Prompt Decoder (VIPD, ~2.1M parameters) is trained via zeroth-order optimization (SPSA) to generate task-aware input-space perturbations: global additive prompts for classification and spatial channel-concatenated maps for segmentation, derived from fused image (MAE ViT-B/16) and anatomical (Uformer) embeddings. In the Probe stage, the trained VIPD is repurposed as an uncertainty instrument: multi-scale perturbations applied to unlabeled samples produce prediction instability scores quantified at both image level (prompt-shift cosine dissimilarity, finite-difference sensitivity) and pixel level (boundary disagreement, volumetric change, pixel entropy). A rank-based fusion criterion with a task-emphasis parameter γ unifies acquisition across classification and segmentation tasks.The paper claims three principal contributions: (1) a unified VIPD producing both prompt types from a shared backbone; (2) multi-scale instability-driven acquisition within a single policy; and (3) a dynamically weighted cross-task training objective. Evaluated on seven public datasets across six clinical modalities, P² claims 40–60% label reduction while matching or exceeding fully supervised baselines. The central empirical finding is that spatial boundary instability signals—designed for segmentation—improve classification sample selection by up to 24.5 AUROC points, suggesting task-unified acquisition is fundamentally superior to task-specific alternatives.

  • Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.

    S1.Well-scoped compound problem formulation. The simultaneous constraints of API opacity and annotation scarcity are genuine deployment bottlenecks in clinical AI. The gap analysis in Section 1 is specific and accurate, clearly positioning P² against VALIANT, BAPS, ZIP, and BlackVIP along three dimensions: black-box compatibility, annotation efficiency, and cross-task unification. No prior work satisfies all three simultaneously, and the paper makes a credible case for this gap.S2.Dual-use of VIPD as both prompt generator and uncertainty instrument. Repurposing a trained prompt decoder for informativeness estimation, without additional parameters or a separate acquisition module ,is an architecturally elegant economy. This avoids the common pitfall of bolting an independent uncertainty estimator onto a prompting framework, and the design consequence (sensitivity to input characteristics is exactly what is needed for sample selection) is intellectually compelling.S3.The cross-task signal transfer finding is scientifically significant. A 24.5-point AUROC drop on CheXpert,a classification-only dataset,from removing boundary disagreement signals alone is the paper’s most striking result. If reproducible and mechanistically validated, this implies that spatial boundary uncertainty is a domain-general proxy for diagnostic ambiguity in medical images, with implications extending well beyond this framework.S4.Breadth and realism of evaluation. Eight benchmarks across six modalities with API-constraint simulation using open-source FMs with all internal access explicitly disabled (BioViL, MedCLIP, MedSAM) is methodologically responsible and unusually broad for this class of paper. This exceeds the evaluation scope of any individual prior method in this space.S5.Practical deployability signal. Reporting convergence within 0.9 pts of FSL at ~50K queries (<1h at 1K queries/min) gives practitioners concrete, actionable guidance on real-world deployment feasibility, a type of analysis absent from most AL papers in medical imaging.

  • Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.

    W1 [Critical]. The feature consistency loss Lfeat = ||F(X+P) − F(X)||² requires evaluation of intermediate representations F(·). Under the strict black-box constraint that defines the paper’s central premise, no access to weights, gradients, or activations, this loss cannot be computed on FM features. If F(·) refers to VIPD-internal features rather than FM features, the loss must be reframed as decoder self-regularization rather than FM feature drift constraint. As written, this is a direct contradiction of the paper’s core claim and must be explicitly resolved.W2 [Critical]. The rank fusion in Eq. 5 (RankFinal = γ·ICls + (1−γ)·ISeg) is a weighted sum of raw scores, not ranks. The abstract and body both use “rank-based fusion,” which is misleading. More substantively, ICls and ISeg are derived from different quantities (cosine dissimilarity + finite-difference sensitivity vs. pixel entropy + boundary Dice + volumetric change) and have different scales and distributions. Without normalization prior to fusion, the combined score will be dominated by the larger-magnitude component in an unpredictable, dataset-dependent manner. No normalization step is described.W3 [Significant]. The diversity loss Ldiv = −D_KL(y_prob || y^p_prob) maximizes KL divergence between original and perturbed outputs without a stabilization bound. Its interaction with the entropy term Lent which penalizes entropy proportional to prompt similarity S ,is not analyzed. When S takes intermediate values, both losses may partially oppose each other, creating unstable gradients. No loss interaction analysis or training stability curves are provided.W4 [Significant]. SPSA optimization at ~2.1M parameters raises unaddressed convergence concerns. The SPSA gradient estimator variance scales as O(d) in parameter dimensionality, making convergence noisier as parameter count grows. No variance analysis, adaptive perturbation schedule, or comparison to alternative zeroth-order methods (e.g., CMA-ES) is provided. Without convergence curves or stability analysis, the claim that zeroth-order training is “practical” at this parameter scale is asserted rather than demonstrated.W5 [Significant]. Baseline selection is inconsistent with the paper’s own threat model. Entropy Sampling is included as a black-box baseline, despite Section 1 explicitly arguing that API-served models do not expose calibrated softmax distributions. Genuinely black-box-compatible alternatives—margin sampling, least-confidence sampling, or diversity-based k-center clustering on image features requiring no FM interaction—are absent from the comparison.W6 [Significant]. The headline result (24.5 AUROC from ωb=0 on CheXpert) rests on a single dataset and single ablation condition. No sample-level analysis establishes what samples are uniquely selected by boundary disagreement, making it impossible to validate the anatomical ambiguity hypothesis against simpler explanations (e.g., CheXpert pathologies such as cardiomegaly and pleural effusion inherently involve complex organ boundaries, which may be a dataset-specific rather than universal phenomenon).W7 [Significant]. Dataset-specific tuning of 10 hyperparameters per dataset (Table 1) using a 3% stratified seed is a substantial methodological concern. The tuning procedure, whether a separate validation split was used, and whether hyperparameter selection consumed annotation budget are not described.W8 [Minor]. An unresolved “Fig. ??” cross-reference appears in Section 3.The abstract cites 92.8% AUROC on CheXpert with 60% labels, but the body reports 91.8% at 50% and 97.6% at 100%—the 92.8% figure is not traceable to any table or figure in the main text. Reference [3] (VALIANT, AAAI 2026, cited anonymously) appears to be prior work from the same group; the incremental technical contribution over VALIANT is not clearly delineated.

  • Please rate the clarity and organization of this paper

    Satisfactory

  • Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.

    The authors claimed to release the source code and/or dataset upon acceptance of the submission.

  • Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?

    N/A

  • Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html

    The cross-task signal transfer finding is genuinely interesting and could constitute the paper’s most significant contribution if properly validated. The authors are encouraged to provide: (1) a sample-level analysis showing which CheXpert images are uniquely selected by boundary disagreement, ideally with their pathology labels—to test the anatomical ambiguity hypothesis; (2) resolution of the Lfeat black-box contradiction, which is the most urgent revision needed; (3) normalization of ICls and ISeg before score fusion in Eq. 5; and (4) error bands on Figure 3 learning curves over the 10 reported runs. The VALIANT relationship should be explicitly addressed with a technical delta statement, as this is relevant to the novelty assessment.

  • Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.

    (4) Weak Accept — marginally above the acceptance threshold, but would not mind if rejected, dependent on rebuttal

  • Please justify your recommendation. What were the major factors that led you to your overall score for this paper?

    P² addresses a well-motivated compound problem and the dual-use VIPD architecture is conceptually elegant. The evaluation breadth is commendable and the cross-task signal transfer finding could be impactful if validated. However, three issues prevent acceptance in current form: (1) the Lfeat feature consistency loss directly contradicts the black-box premise and must be resolved—this is not a minor clarification but a fundamental inconsistency that undermines the paper’s core claim; (2) the score fusion in Eq. 5 lacks normalization, making results unpredictable and dataset-dependent; (3) the VALIANT prior-work relationship is inadequately disclosed, creating uncertainty about the true incremental contribution. The weak baseline selection and missing statistical error bands on learning curves further weaken the experimental case. The paper is closer to acceptance than rejection; targeted revisions addressing items (1) and (2) would substantially strengthen it for resubmission.

  • Reviewer confidence

    Very confident (4)

  • [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.

    Accept

  • [Post rebuttal] Please justify your final decision from above.

    The authors engaged with every single concern I raised — including providing concrete data for W4 (convergence curves, CMA-ES comparison), a sample-level analysis for W6, the min-max normalization specification for W2, and the critical L_self rename for W1.No concern was left completely unaddressed or dismissed. The two critical concerns are both resolved. W1 is resolved by the L_self reframing — the fix is technically correct and eliminates the logical contradiction. W2 is resolved with concrete normalization specification and quantitative evidence that the choice matters but the method is robust. These were the highest bars, and both were cleared. The significant concerns are mostly resolved or substantially mitigated. W4 receives the strongest response — detailed variance reduction mechanisms, monotonically contracting convergence curves, and a direct CMA-ES comparison all provided from what appears to be already-run experiments. W6’s sample-level evidence (62% vs. 31% base rate) combined with cross-dataset replication across four modalities provides reasonable support for the paper’s central finding. W7’s protocol is now clearly described. Two residual concerns remain but do not warrant rejection. W3’s theoretical interaction analysis remains incomplete — the empirical stability evidence is acceptable for a conference paper but the theoretical claim is asserted. W5’s threat model tension — using open-source models that expose probabilities while motivating the work with proprietary APIs that don’t — requires careful revision of the framing, not just a caveat. Both of these can be addressed in the camera-ready without new experiments.



Author Feedback

We thank reviewers for recognizing P2’s compound-problem framing, the dual-use VIPD design, evaluation breadth, and the cross-task transfer finding.

[R1.1/R3.6] CheXpert +24.5 AUROC mechanism. Critical clarification: I_bnd uses NO segmentation GT. At probe time, MedSAM produces predicted boundary maps for the unlabeled CXR (original and perturbed); I_bnd = 1 - Dice(boundary_orig, boundary_pert) measures instability of MedSAM’s own predictions. Mechanism: CheXpert pathologies (cardiomegaly, effusion, atelectasis) have diagnostically informative contours; unstable boundaries indicate ambiguous anatomy, correlated with classification ambiguity. ~62% of I_bnd-uniquely-selected samples carry one of these labels (vs. ~31% base rate) — real cross-task transfer, not supervision leakage. [R1.2/R2.3] L_unified weighting. Each term is naturally bounded — L_task is CE/Dice; L_div, L_ent in ~[0, log K]; L_feat is Lipschitz-bounded on the small VIPD trunk. All four stay within 1.5x of each other through training; no manual coefficient needed (curves added). [R1.3] FSL ceiling. FSL 92.4% uses ViT-B/16 with matched preprocessing and 5-finding eval — within the 0.92-0.94 ViT range. DenseNet-121 is a textual reference, not the FSL backbone. [R1.4/R3.7] Hyperparameter protocol. The 3% stratified seed is the validation split; tuning is random search over 30 trials per dataset, held out from the labeled pool — selection does NOT consume annotation budget. [R1.5] “Fundamentally” overstated. Agreed — replaced with “consistently superior in the medical-imaging setting evaluated”. [R1.6] Statistical test. Paired t-test over 10 runs with Bonferroni correction across all comparisons. [R1.7] Tab.2 ACDC inconsistency. “Ours” uses dataset-specific weights (Tab.1) on top of (alpha_1, gamma); “Equal” fixes ALL weights uniformly. Caption clarified. [R1.8/R3.8] Fig.??/Ref.[3]/ abstract. Cross-refs fixed; abstract 92.8% is P2 at 60% labels (Fig.3). VALIANT delta: it is classification-only black-box AL; P2 adds unified global+spatial prompting from one decoder, segmentation, and cross-task acquisition.

[R3.1] L_feat black-box consistency. Wording bug: F(.) is the VIPD’s OWN MLP-trunk feature (shared 1024-d activation), not FM features. L_feat = ||F_VIPD(X+P) - F_VIPD(X)||^2 is decoder self-regularization; no FM internals accessed. Renamed to L_self. [R3.2] Score normalization. Per-batch min-max (“rank-based” = the resulting ranking): I_hat = (I - min_B)/(max_B - min_B + eps); Rank = gammaI_hat_Cls + (1-gamma)I_hat_Seg. Kvasir@10% Dice / CheXpert@50% AUROC: raw 56.8 / 90.6; min-max 58.5 / 91.8 (reported); Borda-rank 58.2 / 91.7.Eq. 5 corrected. [R3.3] L_div / L_ent interaction. L_div’s KL is bounded by the supervised-loss-anchored perturbation; L_ent’s S-weighting routes entropy to whichever output matches current prompt similarity—complementary, not opposed. Training-loss std < 0.03 after epoch 20.[R3.4] SPSA convergence at 2.1M params. Variance controlled via Rademacher perturbations, Spall decay c_t=c_0/t^0.101, Polyak-Ruppert momentum, and n=8 SPSA/step (~8x reduction). CheXpert (queries/AUROC/std over 10 seeds): 5K : 71.3 / 2.1 10K : 82.4 / 1.4 20K : 88.1 / 0.8 50K : 91.5 / 0.5 100K : 91.8 / 0.4 Std contracts monotonically. CMA-ES at matched budget: 3-5 AUROC worse, ~3x memory. [R3.5] Baselines under strict black-box. Entropy Sampling assumes returned probabilities (open-source FMs comply); caveat stated. Added strictly black-box baselines (CheXpert@50% / Kvasir@10%): Random : 84.2 / 45.0 K-Center : 85.7 / 47.3 Coreset(CLIP) : 87.1 / 49.8 Margin : 88.4 / 51.2 Entropy : 88.9 / 52.6 P2 (Ours) : 91.8 / 58.5

[R2.1] Sec. 2 will be tightened with a notation table. [R2.2] Add vs. concat. Classification uses additive prompts because z_I is a fixed-dim semantic vector—additive fusion preserves geometry without expanding FM input. Segmentation needs spatial alignment, so the spatial prompt is channel-concatenated.




Meta-Review

Meta-review #1

  • Your recommendation

    Invite for Rebuttal

  • Please justify your decision. In case you deviate from the reviewers’ recommendations, explain in detail the reasons why. In case of an invitation for rebuttal, clarify which points are important to address in the rebuttal.

    I am weighing the R2 accept with a lesser coefficient, and, thus, sending paper for the rebuttal.

    Some of the issues from the reviews:

    Iinternal model activations for the feature consistency loss, which directly goes against the black-box assumption the whole paper is built on.

    The acquisition score combines different signals without normalizing them first, so the authors need to show generalizability across datasets.

    Convergence analysis for the large model is needed.

    Contradiction on the entropy sampling black-box regime?

  • After you have reviewed the rebuttal and updated reviews, please provide your recommendation based on all reviews and the authors’ rebuttal.

    Accept

  • Please justify your recommendation.

    The authors delivered a clear and convincing rebuttal; this paper is ready for MICCAI, provided the updates from the rebuttal round are implemented and explained in the paper.



Meta-review #2

  • After you have reviewed the rebuttal and updated reviews, please provide your recommendation based on all reviews and the authors’ rebuttal.

    Accept

  • Please justify your recommendation.

    The paper presents Prompt and Probe, a framework for adapting frozen or API-serve foundation models (FMs) to classification or segmentation in medical imaging. The reviewers acknowledged the novelty and practical motivation for the proposed framework, and found the evaluation quite rigorous, given the high number of models and datasets explored in the paper. Several weaknesses were pointed out, such as i) scale/coefficients of loss terms, ii) design choices, especially for hyperparameter tuning, and iii) inconsistencies between the namings of components (e.g., Lfeat or rank-based fusion) and their actual behavior. During the rebuttal, the authors addressed each reviewer’s points in detail and proposed appropriate changes to the manuscript as needed. I recommend acceptance.



Meta-review #3

  • After you have reviewed the rebuttal and updated reviews, please provide your recommendation based on all reviews and the authors’ rebuttal.

    Accept

  • Please justify your recommendation.

    This submission proposes a unified active visual prompting framework. R2 and R3 liked the approach and dual architecture. R1 noted missing details on hyperparameters. The rebuttal addressed most concerns, and provided missing details. One concern from my side is readibility of figures (zoom in and out multiple times made me dizzy - suggesting enlarging text size for increased visibility and impact). For all these reasons, and with respect to the other submissions, the recommendation is towards Acceptance.



back to top