Visual electrophysiology provides an objective alternative for visual impairment categorization by evaluating stimulus-evoked retinal and neural responses that reflect the functional integrity. However, in practical acquisitions, multichannel recordings frequently suffer from channel missingness caused by sensor failures or environmental interference, leading to degraded robustness in downstream models. While signal reconstruction methods can recover missing channels, conventional approaches often ignore physiological constraints and may introduce hallucinated structures that obscure clinically relevant patterns. In this work, we reformulate it as a physiological consistency-constrained generative task. A domain-specific reconstruction loss is first designed for the GAN-based framework to emphasize stimulus-related waveform regions, preserve multi-scale temporal structure, and constrain magnitude statistics of evoked responses. To address possible failures or noisy cases, an adaptive artifact suppression strategy is further introduced, utilizing a cascaded mixture-of-experts (CMoE) that explicitly models inter-channel dependencies and binocular correlations. Extensive experiments demonstrate that the proposed method substantially improves reconstruction fidelity and provides more accurate impairment gradings.
Links to Paper and Supplementary Materials
Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026/paper/0977_paper.pdf
SharedIt Link: Not yet available
SpringerLink (DOI): Not yet available
Supplementary Material: Not Submitted
Link to the Code Repository
N/A
Link to the Dataset(s)
N/A
BibTex
@InProceedings{YaoChe_Physiologically_MICCAI2026,
author = { Yao, Chenglin AND Liu, Jing AND Wang, Kai AND Yang, Tian AND Han, Zaidao AND Higashita, Risa AND Liu, Jiang},
title = { { Physiologically Consistent Missing Channel Reconstruction and Cascaded MoE for Impairment Categorization from Visual Electrophysiological Signals } },
booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026},
year = {2026},
publisher = {Springer Nature Switzerland},
volume = {LNCS 16896},
month = {September},
page = {pending}
}
Reviews
Review #1
- Please describe the contribution of the paper
The paper proposes a physiologically consistent reconstruction method for visual impairment categorization from electrophysiological signals under missing-channel conditions. The approach leverages a GAN with domain-specific loss functions that enforce waveform and amplitude constraints, and incorporates a CMoE module to model inter-channel and binocular dependencies. Experiments on private and public datasets show encouraging results compared to existing methods.
- Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
1.The manuscript is well-written and organized. 2.The method demonstrates encouraging results compared to baselines.
- Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.
1.The method is not evaluated in terms of computational complexity, and no analysis of runtime or resource requirements is provided. 2.The process for selecting method’s hyperparameters is not described. 3.It is unclear whether the baseline results were reproduced or directly taken from the original papers. This should be explicitly stated to ensure fairness and comparability of the evaluation.
- Please rate the clarity and organization of this paper
Good
- Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.
The submission does not provide sufficient information for reproducibility.
- Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?
N/A
- Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html
N/A
- Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.
(4) Weak Accept — marginally above the acceptance threshold, but would not mind if rejected, dependent on rebuttal
- Please justify your recommendation. What were the major factors that led you to your overall score for this paper?
The method is interesting and demonstrates encouraging results. However, the study lacks an analysis of computational complexity, which is important for evaluating the practical applicability of the proposed approach.
- Reviewer confidence
Somewhat confident (2)
- [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.
N/A
- [Post rebuttal] Please justify your final decision from above.
N/A
Review #2
- Please describe the contribution of the paper
The paper introduces a cascaded framework for handling missing‑channel visual electrophysiology data and classifying visual impairment categories. The authors propose a two‑stage architecture consisting of (1) a GAN‑based module for synthesizing missing electrophysiological channels and reconstructing full multichannel signals, and (2) a cascaded mixture‑of‑experts (CMoE) mechanism to improve classification performance and reduce model hallucinations. The reconstructed signals and expert‑refined representations are further processed using an EfficientNet‑based classifier to predict impairment categories (blind, low‑vision, healthy).
- Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
1- Clear motivation and relevance. The missing‑channel problem is common in electrophysiology, and addressing it improves both data usability and downstream diagnostic reliability. 2- Methodological novelty. The GAN‑based missing‑channel reconstruction tailored to visual evoked signals is innovative in this context. The use of a cascaded mixture‑of‑experts (CMoE) to mitigate hallucination risks and stabilize classification adds methodological value. 3- End‑to‑end pipeline. The integration of reconstruction, expert‑guided representation learning, and an EfficientNet classifier makes the system well structured and coherent.
- Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.
Although the model is applied to a clinical signal modality, the paper does not provide interpretability tools (e.g., signal‑level attribution, expert‑validated feature explanations) that would help clinicians understand model decisions.
- Please rate the clarity and organization of this paper
Satisfactory
- Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.
The submission does not provide sufficient information for reproducibility.
- Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?
N/A
- Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html
N/A
- Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.
(4) Weak Accept — marginally above the acceptance threshold, but would not mind if rejected, dependent on rebuttal
- Please justify your recommendation. What were the major factors that led you to your overall score for this paper?
The paper proposes a meaningful and innovative framework for reconstructing missing electrophysiological channels and classifying visual impairments. The combination of GAN‑based reconstruction and a cascaded mixture‑of‑experts mechanism is novel and well motivated. The method shows improved performance compared to existing baselines, and the application area is clinically relevant.
- Reviewer confidence
Somewhat confident (2)
- [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.
N/A
- [Post rebuttal] Please justify your final decision from above.
N/A
Review #3
- Please describe the contribution of the paper
The core contribution of this paper lies in redefining the reconstruction problem of the missing channels of visual electrophysiological signals as a generation task constrained by physiological laws, and introducing a cascaded MoE mechanism to dynamically suppress hallucination artifacts. Specifically, it includes three aspects. First, a physiological consistency reconstruction loss function was designed, which consists of three parts: weighted multi-scale reconstruction error, statistical matching of the response region, and response amplitude constraint. It explicitly encodes prior knowledge such as the peak and delay of the stimulus response region, guiding GAN to generate numerically accurate and physiologically reasonable signals and avoiding the illusory structure in traditional methods. Secondly, a cascaded MoE model was proposed to dynamically suppress unreliable channels through two-level gating: the first level uses the Transformer and SE modules to perform intra-group weighting on the paired channels of the left and right eyes, and the second level models the dependency relationship between different modalities through cross-group attention, fully utilizing the priors of binocular signal degradation synchronization. Thirdly, comprehensive experiments were conducted on the private dataset SPECCU and the public dataset OculusGraphy, comparing over ten methods including traditional classifiers, missing processing methods, and generative models. This method achieved the best results in terms of accuracy, recall rate, F1 score, QWK, and other metrics. The ablation experiment and visualization also verified the effectiveness of each module.
- Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
This article has the following outstanding advantages. First of all, the problem has clinical value. The lack of multi-channel signals is a practical problem in visual electrophysiological acquisition, which directly affects the robustness of downstream hierarchical models. This article provides a clear discussion on this issue with sufficient motivation. Second, the method is reasonably designed and has a physiological basis. The loss function is based on real physiological laws, and the weight graph is dynamically adjusted according to the statistical characteristics of the signal. CMoE takes advantage of the synchronous prior degeneration of the Siamese channels of the left and right eyes and is designed specifically. Third, the experimental design is comprehensive and rigorous. The author used both private and public datasets. Among them, the public dataset is multi-center data, which verifies its universality. Fourth, the text should be clear and the charts effective. The flowchart in Figure 1 clearly shows this three-stage framework. The table layout is standardized and the key points are highlighted.
- Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.
This article also has several obvious shortcomings. First, novelty still falls under the category of combinatorial innovation. The essence of CMoE is a cascade of Transformer, SE and Cross-Attention. None of these components are original, and the essential differences between this article and existing works are not prominent enough. Second, the parameter sensitivity and theoretical basis of the physiological loss function are insufficient. Multiple parameters (α, β, λg, λp) in the loss function need to be set manually. Although specific values are provided in the text, parameter sensitivity is not discussed, nor are adaptive or theory-driven selection methods offered. This raises doubts about the generalization of this method under different devices or stimulus paradigms. Third, there is insufficient repeatable information. No anonymous code or data link was provided. The training details such as the optimizer type, learning rate scheduling, batch size and the number of training rounds are missing. The data preprocessing steps (sampling rate, filtering, denoising, and normalization methods) are also not elaborated in detail.
- Please rate the clarity and organization of this paper
Good
- Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.
The submission does not mention open access to source code or data, but provides a clear and detailed description of the algorithm to ensure reproducibility.
- Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?
N/A
- Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html
N/A
- Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.
(4) Weak Accept — marginally above the acceptance threshold, but would not mind if rejected, dependent on rebuttal
- Please justify your recommendation. What were the major factors that led you to your overall score for this paper?
I think the main factors for weak acceptance are as follows. The factors supporting reception include: the problem of signal loss has been solved by a new method, which has practical significance for objective vision classification. The ablation experiment confirmed the contributions of Physio Loss and CMoE. The experiment was very thorough, comparing over ten methods and achieving the best results on two datasets. The handwriting is clear and easy to understand. The factors hindering higher scores include: insufficient clinical validation and lack of assessment by doctors; Poor repeatability, no code provided, and lack of training details; Method innovation is combinatorial and lacks theoretical breakthroughs. The dataset is relatively small, with only 805 complete signals. After careful consideration, I believe that the core contribution of this paper - explicitly encoding the physiological prior into the reconstruction loss and supplementing it with a cascading gating mechanism - is novel and effective in the field of visual electrophysiological signal processing. This contribution is sufficient for the MICCAI conference, and thus a weak acceptance is given.
- Reviewer confidence
Confident but not absolutely certain (3)
- [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.
N/A
- [Post rebuttal] Please justify your final decision from above.
N/A
Author Feedback
N/A
Meta-Review
Meta-review #1
- Your recommendation
Provisional Accept
- Please justify your decision. In case you deviate from the reviewers’ recommendations, explain in detail the reasons why. In case of an invitation for rebuttal, clarify which points are important to address in the rebuttal.
Add some discussion about clinical interpretability and use and also details about hyper parameters used in the experiments.