Abstract

Accurate and robust depth estimation from monocular endoscopic video is critical for advancing surgical navigation, 3D reconstruction, and augmented reality applications. However, the non-Lambertian reflectance, dynamic illumination, and interreflections prevalent in endoscopic scenes severely violate the brightness constancy assumption underlying conventional self-supervised methods, leading to significant performance degradation. To address this fundamental challenge, we propose MMIC-EndoDepth: a novel self-supervised framework for endoscopic depth estimation centered on Multi-Mechanism Illumination Correction. At its core lies the Illumination-Aware Photometric Correction Module (IAPC), a learnable and interpretable module that explicitly models and compensates for three distinct photometric distortions, including pixel-wise specular highlights, patch-level exposure variations, and depth-guided global lighting attenuation, prior to geometric reconstruction. Rather than treating illumination as a monolithic nuisance, IAPC decomposes it into physically grounded components and employs a Mixture-of-Experts (MoE) architecture with a spatially adaptive gating mechanism. This enables dynamic selection of the most appropriate correction strategy, aligning with clinical intuition and enhancing model explainability. Stable training is ensured through entropy and load-balancing constraints on the MoE, combined with a warmup strategy to promote effective expert utilization. Extensive experiments on standard endoscopic benchmarks (SimCol and C3VD) demonstrate that MMIC-EndoDepth achieves state-of-the-art performance, significantly outperforming existing self-supervised approaches by about 20%. The source code is publicly available at https://github.com/endoloc/endoloc.

Links to Paper and Supplementary Materials

Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026/paper/3564_paper.pdf

SharedIt Link: Not yet available

SpringerLink (DOI): Not yet available

Supplementary Material: Not Submitted

Link to the Code Repository

N/A

Link to the Dataset(s)

N/A

BibTex

@InProceedings{XuZia_MMICEndoDepth_MICCAI2026,
        author = { Xu, Ziang AND Wang, Jialu AND Wang, Bing},
        title = { { MMIC-EndoDepth: Self-Supervised Endoscopic Depth Estimation with Multi-Mechanism Illumination Correction } },
        booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026},
        year = {2026},
        publisher = {Springer Nature Switzerland},
        volume = {LNCS 16892},
        month = {September},
        page = {pending}
}


Reviews

Review #1

  • Please describe the contribution of the paper

    The main contribution of the paper can be summarized as a self-supervised depth estimation framework designed specifically for challenging endoscopic imaging conditions.

  • Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.

    1.The central contribution of the paper is the introduction of the IAPC module, which is integrated into the training pipeline between view synthesis and the photometric loss computation to correct illumination-induced appearance changes. 2.To further enhance robustness, the method extends IAPC into a multi-scale Mixture-of-Experts (MoE) formulation applied across pyramid levels, where multiple complementary experts predict per-pixel affine photometric transformations such as scale and bias. 3.A pixel-wise gating mechanism is then used to adaptively fuse the outputs of these experts in the parameter space, enabling the model to handle diverse illumination distortions at different scales while performing spatially varying photometric correction.

  • Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.

    1.The design of the depth binning strategy appears to be somewhat imperfect. The paper states that in colonoscopy scenarios, a simple observation is utilized: brightness varies with the distance between the camera and tissue (closer regions are generally brighter, while farther regions are darker). However, in the fourth row of the endoscopic images in Fig. 3, it can be observed that some distant regions still contain bright speckle-like patterns caused by specular reflections. Although the visualizations in Fig. 3 show that MMIC-EndoDepth performs better than other methods, the estimated depth maps still exhibit orange regions in distant areas. Therefore, I am concerned that the depth-based design in this component may potentially interfere with the effectiveness of the pixel-wise and patch-wise photometric correction mechanisms intended to handle illumination distortions. 2.Could the authors elaborate on why an affine photometric model (αI+β) is appropriate for handling complex illumination effects such as specular highlights and inter-reflections? 3.The quantitative impact of the gating mechanism does not appear to be evaluated in the ablation studies. Could the authors clarify this? 4.The paper does not specify the shapes of the final fused α and β maps. My understanding is that both have the same spatial dimensions as the input image (i. e. , H×W), but this appears to be inconsistent with the cube-like illustration shown in Fig. 2. 5.The notation for βqs, βps and αqs, αps appears to be inconsistent between Fig. 2 and the Method section, where the order of the subscripts is reversed or not clearly aligned. 6.In the last line of the paragraph “Expert 3: …”, there is an extra space before the period.

  • Please rate the clarity and organization of this paper

    Good

  • Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.

    The submission has provided an anonymized link to the source code, dataset, or any other dependencies.

  • Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?

    N/A

  • Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html

    N/A

  • Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.

    (5) Accept — should be accepted, independent of rebuttal

  • Please justify your recommendation. What were the major factors that led you to your overall score for this paper?

    The paper addresses a clinically relevant problem in endoscopic depth estimation caused by violations of photometric consistency under non-Lambertian reflectance, dynamic illumination, and inter-reflections. The proposed illumination-aware photometric correction with a mixture-of-experts design is not fundamentally novel, but it is well-motivated and effectively improves robustness under challenging lighting conditions, showing clear empirical benefits. And the main text contains some minor issues.

  • Reviewer confidence

    Very confident (4)

  • [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.

    N/A

  • [Post rebuttal] Please justify your final decision from above.

    N/A



Review #2

  • Please describe the contribution of the paper

    This paper proposes a self-supervised framework (MMIC-EndoDepth) to address photometric inconsistency due to illumination variations (e.g. specular reflections and interreflection), which is a problem in monocular depth estimation in endoscopic images.

    The main contribution is the decomposition of illumination distortion into multiple mechanisms (pixel-level specular, patch-level exposure variations and depth-dependent attenuation), each of which is handled by MoE/ IAPC module. It has been evaluated on SimCol and C3VDdatasets and shows significant performance improvements over existing methods.

  • Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
    • It is important to note that the widely known problem in depth estimation in endoscopy (breakdown of photometric assumptions due to illumination variations) is tackled head-on.

    • The idea of decomposing illumination distortion into multiple mechanisms is reasonable and consistent with endoscope-specific phenomena.

    • The design of the IAPC is clear, and in particular the design of gated fusion in parameter space rather than image space is reasonable from the perspective of study stability.

    • The experiments are carefully conducted and include comparisons with strong baselines such as EndoDAC and AF-SfMLearner.

    • As shown in Table 1, there is a significant improvement (Abs Rel 0.207 → 0.101), particularly in C3VD, with very high performance on the evaluation data.

    • Ablation is also performed appropriately, confirming the contribution of each expert.

  • Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.

    -Although the method is designed to handle illumination distortion by decomposing it into three mechanisms - pixel, patch and depth-bin - it is not clear to what extent this decomposition is valid in a real endoscopic environment. In a real environment, there are complex interactions between body fluids, tissue properties and viewpoint-dependent reflections, so there is uncertainty in the assumption that these can be separated as a limited mechanism.

    -A closer look at the numerical values in Table 3 reveals the following unnatural patterns: these patterns suggest that the increase in model capacity may be dominant, rather than each expert being responsible for an independent lighting phenomenon. In particular, the discontinuous improvement that occurs only when the third expert is added is difficult to reconcile with the interpretation that the design division of labour is actually working. The RMSE for any combination of two converges to 0.418-0.439, and there is no significant difference regardless of which expert is chosen Only when three are combined, there is a non-linear improvement that jumps to RMSE 0.389 Patch alone (0.431) is better than Pixel alone (0.455) and the improvement of Pixel+Patch (0.418) is only slightly better than Patch alone.

    -Limitations of the evaluation environment The evaluation was limited to SimCol and C3VD, both of which are controlled environments (synthetic / phantom), making it difficult to judge their generalisability to real clinical environments. In particular, it is untested whether the core illumination decomposition assumptions of the method are valid in more complex clinical environments.

  • Please rate the clarity and organization of this paper

    Good

  • Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.

    The submission has provided an anonymized link to the source code, dataset, or any other dependencies.

  • Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?

    N/A

  • Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html

    -A closer look at the ablation pattern in Table 3 shows that all combinations of two converge to RMSE 0.418-0.439, with small differences depending on the choice of expert. Only when three are combined does the RMSE improve discontinuously to 0.389, while Patch alone (0.431) is better than Pixel alone (0.455) and the improvement for Pixel+Patch (0.418) is only slightly better than Patch alone. These patterns do not appear to be entirely consistent with the design philosophy that each expert is responsible for an independent illumination phenomenon. It would be helpful to understand better how the authors interpret this point if they could explain in the rebuttal.

    -The evaluation of this method is limited to SimCol (synthetic) and C3VD (phantom), both in controlled environments. It is not obvious whether the assumptions of the proposed illumination decomposition hold true for real-life endoscopic images, where fluid, tissue properties and viewpoint-dependent reflections interact in a more complex manner. The position of the proposed method would be clearer if the authors mention in the rebuttal or in the paper how they are aware of this point and what kind of validation they envisage in the future.

  • Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.

    (3) Weak Reject — marginally below the acceptance threshold, but would not mind if accepted, dependent on rebuttal

  • Please justify your recommendation. What were the major factors that led you to your overall score for this paper?

    The paper is commendable for its novel ideas and careful experiments, showing clear performance improvements on synthetic and phantom data. In particular, the combination of illumination decomposition and MoE is interesting and the methodology is close to a weak accept level.

    On the other hand, an important limitation is that the core of the method relies on assumptions about the illumination structure, the validity of which has not been verified (directly or indirectly) with real data. This issue was judged to have a significant impact on the score, as it is not simply a lack of evaluation, but is directly related to the generalisability of the method. Based on the above, the strengths and weaknesses were comprehensively assessed as WEAK REJECT.

  • Reviewer confidence

    Confident but not absolutely certain (3)

  • [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.

    N/A

  • [Post rebuttal] Please justify your final decision from above.

    N/A



Review #3

  • Please describe the contribution of the paper

    A novel illumination-aware correction module, named IAPC, that handles photometric inconsistencies in colonoscopy video during monocular depth estimation training. The module is used only at training time and helps the model cope with the non-uniform lighting conditions typical of colonoscopy, contributing to state-of-the-art results on both simulation and phantom data

  • Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
    • Novelty: The core of the proposed self-supervised framework is a plugin module that improves endoscopic depth estimation. This innovation stems from the real-world observation that colonoscopy video data exhibits distinctive photometric inconsistencies. These observations were translated into practice through a Mixture of Experts (MoE) approach, where each expert specifically models a different type of inconsistency.
    • Ablation: The ablation study systematically explores the design choices and evaluates the contribution of each Expert, highlighting the module’s robustness. This validation further strengthens confidence in the performance of the proposed method.
  • Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.

    1.The evaluation is conducted exclusively on phantom (C3VD) and synthetic (SimCol) datasets, with no qualitative or quantitative assessment on real clinical colonoscopy data, leaving the generalizability of the proposed method to real-world clinical conditions undemonstrated 2.The presence of mathematical inconsistencies and unclear formulations. For example:

    • with P_base=8 and s={0,1,2,3}, the max operator in Eq. 4 is redundant since P_base / 2^s >=1 for all s
    • The term on the right-hand side of Equation 6 is redundant, since the softmax operation across all k values ensures that sum_k(w_s^k(u)) = 1
    • The statement, “The expert predicts an image-level affine pair for each bin,” is somewhat unclear. Need to clarify whether this prediction is accomplished using a 3x3 convolutional layer as well.
    • In Equation 8, the pixel-wise gates are inherently positive and sum to 1, so it is unnecessary to explicitly state this.
    • Is the variable tau in Eq. 6 considered a hyperparameter ?
  • Please rate the clarity and organization of this paper

    Good

  • Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.

    The authors claimed to release the source code and/or dataset upon acceptance of the submission.

  • Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?

    N/A

  • Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html

    The authors claim to release the source code and/or dataset upon acceptance, which is appreciated; however, the provided link does not currently contain any code. I look forward to its release upon acceptance.

    minor comments:

    • Although Fig. 1 illustrates photometric inconsistencies, it does not make clear how these variations impact overall depth estimation. It would be helpful to include a visual demonstration of how each type of photometric inconsistency influences depth estimation, as this is central to the paper’s objective.
    • The use of the term “pyramid” in Subsection 2.2 is somewhat unclear, as it is not referenced in the Lite-mono [15] paper. This could cause confusion, so additional clarification would be helpful
    • The text in Fig. 2, particularly in Fig. 2(b), is extremely small and is almost unreadable
  • Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.

    (4) Weak Accept — marginally above the acceptance threshold, but would not mind if rejected, dependent on rebuttal

  • Please justify your recommendation. What were the major factors that led you to your overall score for this paper?

    This paper presents a well-motivated contribution. The IAPC module is a principled response to real-world photometric inconsistencies in colonoscopy video, the ablation study is thorough, and the performance improvements over existing methods are substantial. However, the evaluation on phantom and synthetic data only leaves generalization to real clinical conditions undemonstrated, and several mathematical inconsistencies across Equations 4, 6, and 8 require attention

  • Reviewer confidence

    Confident but not absolutely certain (3)

  • [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.

    N/A

  • [Post rebuttal] Please justify your final decision from above.

    N/A



Author Feedback

N/A




Meta-Review

Meta-review #1

  • Your recommendation

    Provisional Accept

  • Please justify your decision. In case you deviate from the reviewers’ recommendations, explain in detail the reasons why. In case of an invitation for rebuttal, clarify which points are important to address in the rebuttal.

    The reviewers agree that the paper addresses a key limitation of self-supervised endoscopic depth estimation—illumination-induced violation of photometric consistency—through a novel and well-motivated IAPC module with multi-scale MoE experts and pixel-wise gated fusion in parameter space. They also highlight the clear module design, strong improvements over competitive baselines, and systematic ablation studies demonstrating the contribution and robustness of each expert.



back to top