List of Papers Browse by Subject Areas Author List
Abstract
Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying solely on isotropic preprocessing for anisotropic CT segmentation.
Links to Paper and Supplementary Materials
Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026/paper/3539_paper.pdf
SharedIt Link: Not yet available
SpringerLink (DOI): Not yet available
Supplementary Material: Not Submitted
Link to the Code Repository
N/A
Link to the Dataset(s)
N/A
BibTex
@InProceedings{LiJia_MAGEFormer_MICCAI2026,
author = { Li, Jiaying AND Remagnino, Paolo},
title = { { MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation } },
booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026},
year = {2026},
publisher = {Springer Nature Switzerland},
volume = {LNCS 16884},
month = {September},
page = {pending}
}
Reviews
Review #1
- Please describe the contribution of the paper
This paper makes the contribution of reframing anisotropic CT segmentation as a metric-consistency problem rather than a preprocessing issue, and introduces a geometry-aware Transformer framework that explicitly models physical spacing throughout encoding, feature interaction, and inference. This leads to improved segmentation performance, especially in terms of boundary accuracy on anisotropic abdominal CT benchmarks.
- Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
This paper addresses a well-motivated and under-explored issue in anisotropic CT segmentation by explicitly modeling the mismatch between physical voxel spacing and the isotropic geometric assumptions of standard volumetric Transformers. The proposed framework is conceptually clean, with the three components targeting metric consistency at complementary stages of the pipeline, which gives the method a clear unifying principle. The experimental section is also solid: the use of a unified evaluation protocol improves the credibility of the comparison, and the reported gains in HD95, small-organ performance, and robustness under increasing anisotropy make the empirical case convincing. Overall, the work is technically sound, practically relevant, and supported by reasonably thorough validation.
- Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.
1.The paper repeatedly contrasts the proposed framework with “isotropic preprocessing” in the abstract, introduction, and conclusion, but it is not sufficiently clear what specific preprocessing pipeline this term refers to in practice, or whether this comparison is experimentally controlled. 2.Fig. 3 provides helpful qualitative evidence for the anatomical plausibility of the proposed method, and this part would be even stronger if accompanied by a dedicated anatomy-aware or topology-aware quantitative metric. 3.The ablation in Table 3 clearly shows that all proposed components contribute positively to the final performance. It would nevertheless be helpful to report the computational overhead of the full framework more explicitly, so that readers can better assess the performance-efficiency tradeoff introduced by the geometry-aware design.
- Please rate the clarity and organization of this paper
Good
- Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.
The submission does not mention open access to source code or data, but provides a clear and detailed description of the algorithm to ensure reproducibility.
- Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?
N/A
- Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html
N/A
- Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.
(5) Accept — should be accepted, independent of rebuttal
- Please justify your recommendation. What were the major factors that led you to your overall score for this paper?
This paper addresses a relevant and under-explored problem in anisotropic CT segmentation, and presents a technically sound framework with promising results, especially on boundary-related metrics. The method is well motivated, although there is still room for improvement in clarifying some experimental claims and in providing more complete quantitative and efficiency analysis.
- Reviewer confidence
Very confident (4)
- [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.
Accept
- [Post rebuttal] Please justify your final decision from above.
The authors have addressed my concerns well.
Review #2
- Please describe the contribution of the paper
The paper addresses a practically important yet often under-modeled issue in volumetric CT segmentation, namely the mismatch between isotropic modeling assumptions in standard Vision Transformer pipelines and the anisotropic physical sampling of clinical CT. To tackle this, the authors propose MAGEFormer, a geometry-calibrated framework that injects metric consistency into three stages of the pipeline: metric-adaptive spatial embedding for positional encoding, geometry-constrained attention for cross-scale interaction, and geometric view voting for inference-time discretization reduction. The paper further presents a unified evaluation on BTCV and FLARE22 and reports improved boundary accuracy and competitive Dice performance over several strong CNN- and Transformer-based baselines.
- Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
The method is conceptually coherent. The proposed components are aligned with the central claim and form a reasonably consistent geometry-aware framework. Besides, the method shows improved HD95 and competitive Dice on BTCV and FLARE22 under a unified protocol, with ablations that generally support the design choices.
- Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.
The major weakness is the limited experimental positioning against prior anisotropy-aware methods. Although the paper is explicitly motivated by anisotropic CT and argues that metric-consistent internal calibration is preferable to handling anisotropy only through preprocessing or localized heuristics, the experimental comparison is made mainly against generic backbones such as nnU-Net, UNETR, Swin-UNETR, and U-Mamba. However, the paper itself notes that prior work has already explored more direct thickness-aware adaptation, including AlignShift, which is specifically introduced as an explicit architectural solution for anisotropic volumes. A direct comparison with such methods would make the paper’s empirical claims considerably more convincing.
- Please rate the clarity and organization of this paper
Good
- Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.
The submission does not mention open access to source code or data, but provides a clear and detailed description of the algorithm to ensure reproducibility.
- Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?
N/A
- Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html
N/A
- Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.
(4) Weak Accept — marginally above the acceptance threshold, but would not mind if rejected, dependent on rebuttal
- Please justify your recommendation. What were the major factors that led you to your overall score for this paper?
I recommend this paper for weak accept because it addresses a real and practically relevant problem in medical image segmentation, namely the mismatch between isotropic volumetric modeling assumptions and anisotropic clinical CT acquisition. The paper is well motivated, clearly written, and proposes a coherent geometry-aware framework that consistently incorporates physical spacing information into positional encoding, cross-scale interaction, and inference. The experimental results on BTCV and FLARE22 are solid, particularly in terms of boundary accuracy, and the ablation study generally supports the contribution of each component.
My main concern is the experimental positioning. Although the method is presented as a solution tailored to anisotropic CT, the comparisons are mostly against general segmentation backbones rather than more direct anisotropy-aware or thickness-aware methods. This makes the empirical claim less convincing than it could be. I also think the methodological novelty is moderate: the work is thoughtful and well executed, but it feels more like a geometry-aware refinement of existing frameworks than a clearly new segmentation paradigm. Overall, I think the paper is good enough to be accepted, but only marginally so.
- Reviewer confidence
Confident but not absolutely certain (3)
- [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.
Accept
- [Post rebuttal] Please justify your final decision from above.
N/A
Review #3
- Please describe the contribution of the paper
This work addresses the geometric metric mismatch caused by anisotropy in CT imaging by proposing a novel Transformer-based framework, MAGEFormer. It introduces geometric constraints at three levels—positional encoding, cross-scale attention, and the inference stage. The overall methodology is clearly structured, the problem formulation is well-motivated, and the approach demonstrates a certain degree of novelty and clinical relevance. The paper reports performance improvements on the BTCV and FLARE22 datasets, validating the effectiveness of the proposed method in enhancing boundary accuracy.
- Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
1.The paper points out that ViTs assume an isotropic grid, whereas CT data are inherently anisotropic; this “metric mismatch” is a practically meaningful problem. 2.MASE, GCA, and GVV operate at the encoding, feature interaction, and inference stages respectively, forming a closed-loop design. 3.The method shows more pronounced improvements on anisotropy-sensitive organs such as the adrenal glands and pancreas, which aligns with the intended design.
- Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.
1.The proposed modules are closely related to existing methods (e.g., RoPE, attention bias, and TTA), and lack clear distinctive innovation. Specifically, MASE is similar to extensions of RoPE; GCA resembles relative position bias; and GVV is comparable to test-time augmentation. 2.The paper does not report model parameters, FLOPs, or inference time, making it difficult to assess the practical computational cost. 3.Figure 1 is relatively complex and not very easy to interpret.
- Please rate the clarity and organization of this paper
Satisfactory
- Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.
The submission does not mention open access to source code or data, but provides a clear and detailed description of the algorithm to ensure reproducibility.
- Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?
N/A
- Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html
N/A
- Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.
(4) Weak Accept — marginally above the acceptance threshold, but would not mind if rejected, dependent on rebuttal
- Please justify your recommendation. What were the major factors that led you to your overall score for this paper?
The paper proposes a geometry-consistent modeling framework to address anisotropy in CT imaging. The motivation is well-founded and the experiments are thorough, but the methodological novelty is still relatively incremental.
- Reviewer confidence
Confident but not absolutely certain (3)
- [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.
N/A
- [Post rebuttal] Please justify your final decision from above.
N/A
Author Feedback
We thank the reviewers (R1–R3) for recognizing MAGEFormer’s geometry-aware design and consistent boundary-accuracy improvements.
Experimental scope and positioning vs. AlignShift (R2). AlignShift is cited in our introduction as a representative anisotropy-aware operator-level design, complementary in scope. It is a TSM-inspired, parameter-free 2D-to-3D operator validated for lesion detection on DeepLesion with 2D-pretrained backbones. MAGEFormer instead asks whether the physical spacing metric should be embedded inside a 3D Transformer’s representation, interaction, and inference. A direct benchmark would entangle the metric-consistency question with three confounding axes: task (detection vs. segmentation), backbone (2D-converted vs. native 3D Transformer), and operator-vs-representation locus. We therefore follow the canonical 3D protocol on BTCV/FLARE 22 with standard 3D baselines (nnU-Net, UNETR, Swin-UNETR, U-Mamba, TransUNet) under identical folds, input crop, training schedule, and metric pipeline. Existing evidence isolates the contribution: As shown in Table 3 (+9.24 Dice / −64.63 mm HD95 vs. same-backbone baseline); and Fig. 2(a) shows the gain widens with anisotropy ratio r (n=80), a trend reproduced under synthetic z-degradation in Fig. 2(b). An operator-level cross-paradigm comparison is left to future work.
Paradigm / Novelty (R2, R3). Our contribution is structural, not operator-level: physical spacing is promoted from a preprocessing input to a first-class representation variable propagated across encoding, interaction, and inference. Within this framing, MASE, GCA, and GVV instantiate one substrate (the spacing metric G^(0) and its stage-wise propagation s^(ℓ)) at three loci where anisotropic mismatch enters: intra-scale self-attention, cross-scale skip alignment, and inference-time discretization. The surface resemblance to RoPE, relative bias, and TTA is therefore only operator-level: those mechanisms operate on voxel indices rather than enforce metric consistency across stages. Table 3 confirms this complementarity: each component contributes (MASE −38.07 / GCA −40.94 / GVV −12.26 mm HD95) yet their composition is strictly stronger (MASE+GCA 18.76 mm; full 10.58 mm), with the gap widening in the high-anisotropy regime predicted by the design (Fig. 2a–b).
Computational efficiency (R1, R3). MAGEFormer is backbone-preserving; the added parameters reduce to a few head-shared scalars per stage (γ̂^(ℓ), τ̂^(ℓ), r̂_a^(ℓ)), a count negligible relative to the backbone. MASE re-parameterizes the existing rotary phase via voxel spacing with no new weights (Sec. 2.2); GCA reuses windowed cross-attention with a shared metric-derived bias (Eq. 6, Sec. 2.3); GVV is parameter-free (Sec. 2.4). At inference, MAGEFormer with GVV matches flip/rotation TTA with a ~4× speedup (Fig. 2c). Table 3 also exposes a trade-off: MASE+GCA without GVV (single-pass, backbone-equivalent cost) attains 0.8295 / 18.76 mm; enabling GVV refines this to 0.8411 / 10.58 mm when boundary fidelity is prioritized.
Other clarifications (R1, R3). By “isotropic preprocessing” we mean the conventional resampling/normalization setting where models operate on voxel-index neighborhoods as if geometrically uniform; this is not a separately tuned baseline, and we will make this explicit. Boundary evidence already combines HD95 with per-organ results on anisotropy-sensitive structures (adrenal glands, pancreas), with robustness (Fig. 2a–b), and with qualitative fragmentation/void cases (Fig. 3); topology-aware metrics are a useful complementary axis. Fig. 1 will be revised to separate architectural flow from geometric motivation.
Meta-Review
Meta-review #1
- Your recommendation
Invite for Rebuttal
- Please justify your decision. In case you deviate from the reviewers’ recommendations, explain in detail the reasons why. In case of an invitation for rebuttal, clarify which points are important to address in the rebuttal.
The paper focused ona under explored problem with technical innovation. Reviewers has minor concerns that the authors can address.
- After you have reviewed the rebuttal and updated reviews, please provide your recommendation based on all reviews and the authors’ rebuttal.
Accept
- Please justify your recommendation.
The AC thinks the paper provides limited insights on medical segmentation tasks, but the paper is of high quality and well written. Reviewers also agreed on the metrics and contribution. Recommend accept.
Meta-review #2
- After you have reviewed the rebuttal and updated reviews, please provide your recommendation based on all reviews and the authors’ rebuttal.
Accept
- Please justify your recommendation.
As noted by the reviewers, considering the effects of voxel spacing on medical image segmentation is clinically relevant and interesting. The reviewers’ comments are minor and have been adequately addressed in the rebuttal. Therefore, I recommend acceptance.
Meta-review #3
- After you have reviewed the rebuttal and updated reviews, please provide your recommendation based on all reviews and the authors’ rebuttal.
Accept
- Please justify your recommendation.
This paper proposes MAGEFormer, a geometry-calibrated Transformer framework for anisotropic CT segmentation. It embeds physical voxel spacing as a first-class representation variable through three components: Metric-Adaptive Spatial Embedding (MASE) for spacing-calibrated positional frequencies, Geometry-Constrained Attention (GCA) for suppressing physically implausible feature correlations, and Geometric View Voting (GVV) for inference-time discretization-bias reduction. Evaluated on BTCV and FLARE22 under a unified protocol against CNN and Transformer baselines, the method achieves strong boundary accuracy (10.58 mm HD95 on BTCV, 3.40 mm HD95 on FLARE22) with consistent Dice gains.Reviewers agreed that the metric-mismatch problem is practically meaningful and under-explored, the three components form a coherent closed-loop design across encoding/interaction/inference stages, the empirical gains on anisotropy-sensitive organs (adrenal, pancreas) align with the design intent, and the unified evaluation protocol increases comparison credibility. They raised several concerns: (1) the “isotropic preprocessing” baseline is not clearly defined or experimentally controlled; (2) anisotropy-aware baselines such as AlignShift are not directly compared; (3) computational overhead (parameters, FLOPs, inference time) was not initially reported; (4) the components are surface-similar to RoPE, relative position bias, and TTA, raising novelty concerns; (5) topology-aware or boundary-specific quantitative metrics could strengthen Fig. 3’s anatomical plausibility claims; and (6) Figure 1 is complex and not easy to interpret.After rebuttal, the authors reframed the contribution as structural (promoting physical spacing to a first-class metric variable propagated across stages) rather than operator-level, clarified that AlignShift comparison would entangle multiple confounding axes (task, backbone, locus), explained computational efficiency (negligible added parameters, GVV ~4× faster than flip/rotation TTA), and defined the “isotropic preprocessing” terminology. All three reviewers maintain or raise their recommendations to Accept.