List of Papers Browse by Subject Areas Author List
Abstract
Accurate endoscopic stereo reconstruction is essential for disease diagnosis and 3D visualizations in surgery. To achieve endoscopic stereo reconstruction from endoscopic stereo images under specular reflections, illumination variations, and smooth texture conditions, we propose the endoscopic stereo reconstruction transformer (ESRT). ESRT captures fine-grained textures by introducing a row-wise cross-attention mechanism that explicitly constrains correspondence search along the horizontal direction and prevents attention from being computed over geometrically invalid regions. Furthermore, we present a distillation-based training strategy that transfers geometric knowledge from a pretrained model without requiring endoscopic 3D annotations. The proposed method achieves the best performance on the SCARED dataset while maintaining real-time efficiency.
Links to Paper and Supplementary Materials
Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026/paper/4268_paper.pdf
SharedIt Link: Not yet available
SpringerLink (DOI): Not yet available
Supplementary Material: Not Submitted
Link to the Code Repository
N/A
Link to the Dataset(s)
N/A
BibTex
@InProceedings{ChaJiu_ESRT_MICCAI2026,
author = { Chang, Jiun-Feng AND Tsai, Po-Wei AND Shen, Chih-Tsung AND Huang, Chun-Rong},
title = { { ESRT: Endoscopic Stereo Reconstruction Transformer } },
booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026},
year = {2026},
publisher = {Springer Nature Switzerland},
volume = {LNCS 16892},
month = {September},
page = {pending}
}
Reviews
Review #1
- Please describe the contribution of the paper
The paper proposes ESRT, a transformer-based method for endoscopic stereo reconstruction. The main idea is to use row-wise cross-attention to restrict stereo matching along the horizontal direction, together with a distillation strategy that learns from a pretrained 3D reconstruction model without using endoscopic 3D annotations. The method is tested on the SCARED dataset and reports better depth metrics than several existing endoscopic reconstruction methods.
- Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
The paper addresses an important problem, as depth estimation and 3D reconstruction in endoscopy are clinically useful but technically difficult due to specular reflection, weak texture, and unstable correspondence. The row-wise attention design is reasonable for stereo endoscopy, since disparity mainly occurs along the horizontal direction and this constraint can reduce unnecessary matching and computation. The reported efficiency is also a positive point, with fewer parameters, lower GFLOPs, and about 44 FPS compared with DUSt3R. The experiments cover several recent endoscopic reconstruction methods, and the visual examples look better than some baselines in selected cases.
- Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.
1.The paper mainly combines a transformer reconstruction framework, epipolar/row-wise matching, and teacher-student distillation. These ideas have already appeared in related forms in stereo matching, transformer-based 3D reconstruction, and model distillation. DUSt3R already performs dense 3D reconstruction with cross-view matching, while Endo-FASt3r and EndoSfM3D have explored foundation-model-based endoscopic reconstruction. The paper does not make the difference from these works sufficiently clear. 2.The distillation strategy is also rather standard. Using DUSt3R as a teacher and training a smaller student model is useful, but the formulation itself does not seem very new. More analysis is needed to show why this distillation is specifically suited to endoscopic stereo reconstruction, rather than being a straightforward compression/adaptation of an existing teacher model. 3.The comparison is not fully convincing. Many baseline results are directly taken from previous papers, but the training and evaluation settings may not be exactly the same. It would be better to rerun key baselines under the same protocol, especially DUSt3R, Endo-FASt3r, and EndoSfM3D. 4.The clinical claim is overstated. The paper mentions real-time clinical applicability, but the experiments are only on SCARED, which is based on porcine cadaver data. There is no validation on real clinical gastroscopy cases, no lesion measurement task, and no user study with clinicians.
- Please rate the clarity and organization of this paper
Satisfactory
- Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.
The submission does not mention open access to source code or data, but provides a clear and detailed description of the algorithm to ensure reproducibility.
- Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?
N/A
- Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html
N/A
- Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.
(4) Weak Accept — marginally above the acceptance threshold, but would not mind if rejected, dependent on rebuttal
- Please justify your recommendation. What were the major factors that led you to your overall score for this paper?
1.The paper mainly combines a transformer reconstruction framework, epipolar/row-wise matching, and teacher-student distillation. These ideas have already appeared in related forms in stereo matching, transformer-based 3D reconstruction, and model distillation. DUSt3R already performs dense 3D reconstruction with cross-view matching, while Endo-FASt3r and EndoSfM3D have explored foundation-model-based endoscopic reconstruction. The paper does not make the difference from these works sufficiently clear. 2.The distillation strategy is also rather standard. Using DUSt3R as a teacher and training a smaller student model is useful, but the formulation itself does not seem very new. More analysis is needed to show why this distillation is specifically suited to endoscopic stereo reconstruction, rather than being a straightforward compression/adaptation of an existing teacher model. 3.The comparison is not fully convincing. Many baseline results are directly taken from previous papers, but the training and evaluation settings may not be exactly the same. It would be better to rerun key baselines under the same protocol, especially DUSt3R, Endo-FASt3r, and EndoSfM3D. 4.The clinical claim is overstated. The paper mentions real-time clinical applicability, but the experiments are only on SCARED, which is based on porcine cadaver data. There is no validation on real clinical gastroscopy cases, no lesion measurement task, and no user study with clinicians.
- Reviewer confidence
Very confident (4)
- [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.
N/A
- [Post rebuttal] Please justify your final decision from above.
N/A
Review #2
- Please describe the contribution of the paper
This paper presents a transformer-based feedforward 3D reconstruction method for endoscopy. The model takes in a stereo pair of images and outputs the point cloud. The authors utilize epipolar constraints and teacher-student distillation.
- Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
- Strong results. Out of the comparisons provided by the authors, their approach (ESRT-Row) achieves best performance in depth estimation
- Effective ideas. student outperforms teacher despite the latter being frozen, demonstrating that the epipolar constraint and multiscale encoder are helpful
- Practicality. The authors demonstrate that their model is efficient compared to some baselines. Furthermore, their method seems like it does not require ground truth and is trained only with pseudolabels.
- Good writing. The method is clearly described and the paper flows well
- Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.
- Limited method novelty. Row-wise (or epipolar constrained) transformer-based 3D reconstruction/depth estimation/stereo matching is fairly dated, and the first work of its kind also includes SCARED in their experiments (STTR Stereo Transformer, Li et al). The method is DUSt3R pointmap prediction + distillation + epipolar constraints, which has limited novelty
- Lack of ablation. For this type of study, the lack of thorough ablation is concerning, even though there are many components that raise several questions. How does distillation compare with train-from-scratch and full supervision from SCARED GT? How do the different loss term ideas contribute? How does DiNAT compare with other backbones like plain ViT (DINOv2-pretrained for instance) or Swin?
- Limited evaluation. Since this is stereo depth estimation, I am curious how the proposed model compares against methods like FoundationStereo, RAFT-Stereo, CREO-stereo, etc. Furthermore, DUSt3R is a originally a two-view reconstruction model. Would using FoundationStereo or another stereo model as a teacher be better since it’s more well-suited for this task?
- I am unsure if the entire training pipeline requires any ground truth data for training, or if the training only comes from pseudolabels from the teacher. Was any SCARED ground truth data used for training? Please clarify.
- Writing. I am unsure if the paper does indeed propose a “reconstruction transformer”. The proposed model seems to be more of a stereo depth estimator. Perhaps this claim can be made if other non-stereo datasets were also used to evaluate the model (e.g., C3VD). There are also other writing concerns, like the paper being motivated in the Introduction section with gastroscopy, but the method is only evaluated with ex-vivo porcine data.
- Please rate the clarity and organization of this paper
Satisfactory
- Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.
The submission does not mention open access to source code or data, but provides a clear and detailed description of the algorithm to ensure reproducibility.
- Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?
N/A
- Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html
N/A
- Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.
(3) Weak Reject — marginally below the acceptance threshold, but would not mind if accepted, dependent on rebuttal
- Please justify your recommendation. What were the major factors that led you to your overall score for this paper?
Please clarify the above concerns. The paper is well-scoped and demonstrates good ideas. Ultimately, my biggest concerns are in the lack of novelty, lack of ablation studies, and the framing of a reconstruction work rather than depth estimation.
- Reviewer confidence
Very confident (4)
- [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.
N/A
- [Post rebuttal] Please justify your final decision from above.
N/A
Review #3
- Please describe the contribution of the paper
This paper addresses the clinical task of endoscopic 3D reconstruction, targeting critical challenges in endoscopic imaging including specular reflections, illumination variations, smooth textures, and unstable depth estimation. It presents the Endoscopic Stereo Reconstruction Transformer (ESRT). Its main contributions are summarized as follows: 1) It introduces a row-wise cross-attention mechanism that enforces horizontal epipolar constraints to reduce geometric ambiguity and invalid correspondences. 2) It employs a distillation-based training strategy that leverages a generic pre-trained model as the teacher network, enabling the transfer of geometric priors without requiring endoscopic 3D annotations. 3) It constructs a lightweight multi-scale encoder-decoder architecture based on DiNAT, which achieves state-of-the-art performance on the SCARED dataset while realizing real-time inference at 44 FPS.
- Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
1) Precise problem formulation: The work accurately targets real-world clinical challenges in endoscopy. The three key objectives enforcing epipolar constraints, alleviating annotation scarcity, and achieving real-time performance are highly consistent with the clinical translation-oriented goals of MICCAI medical imaging research. 2) Effective core innovation: The proposed row-wise cross-attention is simple and physically meaningful, which directly conforms to the horizontal disparity property of stereo endoscopy. The motivation is solid and the design is reasonable. 3) Practical training strategy: The knowledge distillation scheme successfully addresses the shortage of endoscopic 3D annotations, aligns with the mainstream trend of self-supervised/weakly-supervised learning in medical imaging, and exhibits strong extensibility.
- Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.
1) Over-reliance on the distillation strategy: The paper does not thoroughly discuss or analyze the quality of the “pseudo ground truth” provided by the teacher model under domain differences, nor the potential systematic biases. It remains unclear whether the method is overly dependent on the teacher model. 2) Insufficient ablation studies: The paper lacks complete and independent ablation studies for the three core components: row-wise cross-attention, knowledge distillation, and multi-scale fusion. As a result, the actual quantitative gains of each module cannot be verified.
- Please rate the clarity and organization of this paper
Satisfactory
- Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.
The submission does not mention open access to source code or data, but provides a clear and detailed description of the algorithm to ensure reproducibility.
- Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?
N/A
- Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html
N/A
- Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.
(4) Weak Accept — marginally above the acceptance threshold, but would not mind if rejected, dependent on rebuttal
- Please justify your recommendation. What were the major factors that led you to your overall score for this paper?
1) The research topic is highly consistent with clinical demands, as endoscopic 3D reconstruction is a key technology for surgical navigation and disease diagnosis. 2) The core innovation, row-wise cross-attention, features clear motivation, original design, and remarkable effectiveness, resolving critical limitations of Transformers in endoscopic stereo matching. 3) The method achieves state-of-the-art accuracy while enabling real-time inference, demonstrating high clinical translation value.
- Reviewer confidence
Very confident (4)
- [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.
Accept
- [Post rebuttal] Please justify your final decision from above.
My decision is to accept this paper, because there is a high likelihood that the proposed row-wise cross-attention will produce strong effects in endoscopy or other stereo matching scenarios. However, due to space limitations or other reasons, the ablation study section is relatively limited.
Review #4
- Please describe the contribution of the paper
This paper proposes a Transformer-based framework (ESRT) for 3D reconstruction from endoscopic stereo images. Based on the assumption that stereo correspondences exist mainly in the horizontal direction, the correspondence search is restricted to the horizontal direction by introducing row-wise cross-attention, thereby suppressing attention computation to geometrically invalid regions. In addition, a distillation-based learning strategy using a pre-trained model (DUSt3R) as a teacher allows learning without 3D annotation; the best performance is reported at AbsRel 0.048 compared to existing methods on the SCARED dataset.
- Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
(1) Endoscopic stereo reconstruction is an important issue in clinical applications and the significance of addressing it is clear. (2) )The design of restricting the correspondence search to the horizontal direction by row-wise cross-attention is a reasonable architectural choice that reflects the stereo geometry and contributes to the reduction of computational cost. (3) The distillation-based learning strategy is practical in that it allows learning without 3D annotation, which is difficult to obtain in the endoscopic domain. The design to weight the training signal according to the confidence of the teacher by confidence-aware loss is also reasonable. (4) The proposed method achieves an inference speed of 44fps with 154.45M parameters, about 29% of DUSt3R (532.34M) and 20% of GFLOPs, showing a significant improvement in terms of efficiency.
- Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.
(1) There is a fundamental discrepancy between the claims of the paper and the validation domain. This thesis is positioned throughout as a method for gastroscopy and gastric mucosa. Specifically, the Abstract and Section 1 as a whole are motivated in the context of gastric cancer and precancerous lesion diagnosis, while Section 2.3 states that the proposed decoder “better represents the gastric mucosa during correspondence matching‘ and the Conclusion states that ’we plan to apply the method for gastric cancer and precancerous lesion diagnosis”. However, the experiments are based only on the SCARED dataset (‘acquired from fresh porcine cadaver abdominal anatomy’), which is intraperitoneal data from porcine cadavers, and both the target tissue and imaging conditions are different from the gastric SCARED is different from the gastric mucosa in both target tissues and imaging conditions. Therefore, the gastric mucosa-specific nature repeatedly claimed in the paper is not supported at all experimentally. The architecture of the proposed method itself also consists of a general multi-scale feature extraction and attention mechanism, with no explicit gastric mucosa-specific design elements. Thus, the basis for claims such as ‘better represent the gastric mucosa’ is unclear. To resolve this discrepancy, either (i) the entire article needs to be reorganised into a general stereoendoscopic reconstruction and the gastric mucosa-specific claims removed, or (ii) an evaluation with data closer to the target domain, such as ex-vivo gastric tissue, should be presented. Both directions are beyond the scope of what can be addressed in the REBUTTAL and require essential revisions. (2) The paper reports only AbsRel, SqRel, RMSE and RMSELog and lacks threshold-based accuracy measures (δ < 1.25, δ < 1.25², δ < 1.25³), which are standard in the endoscopic depth estimation field. The group of endoscopic depth estimation-based methods listed for comparison (AF-SfMLearner, DARES, EndoDAC, Endo-FASt3r, EndoSfM3D) all report these δ indicators and are more than comparable with these methods in the same table, It is desirable to have the same indicators; the lack of δ indicators undermines the completeness of the comparison and makes it difficult for the reader to relate the present method to existing endoscopic depth estimation benchmark results.
- Please rate the clarity and organization of this paper
Satisfactory
- Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.
The submission does not mention open access to source code or data, but provides a clear and detailed description of the algorithm to ensure reproducibility.
- Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?
N/A
- Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html
1) row-wise cross-attention is designed on the assumption that the corresponding points are in the same image row, which is strictly a geometric relation that is only valid for rectified stereo inputs. Although the paper describes ‘stereo endoscopes produce disparity mainly along the horizontal direction’, the presence or absence of rectification for SCARED data and the details of pre-processing are not explicitly stated. In order to clarify the conditions for application of the method, it would be desirable to add a sentence about the input image being rectified and the pre-processing for this purpose.
2))) Section 3 states that ‘The inference FPS of ESRT is around 44.Such results show the efficiency of our method compared with SOTA transformer-based methods.’ The hardware used for the comparison, the input resolution and the batch size are not given (‘The training is performed on a computer with two 4090 GPUs~’ is not an accurate hardware description). This is not an accurate description of the hardware). Also, while a comparison of the number of parameters and GFLOPs with DUSt3R is useful, the results for fps under comparable conditions need to be stated side by side.
- Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.
(2) Reject — should be rejected, independent of rebuttal
- Please justify your recommendation. What were the major factors that led you to your overall score for this paper?
The paper contains interesting technical elements: efficient stereo correspondence estimation with row-wise cross-attention and a distillation-based learning strategy. However, despite the fact that the entire paper claims to target gastroscopy and gastric mucosa, the experiments are based only on SCARED, which is laparoscopic data, and there is a fundamental discrepancy between the claimed target domain and the validation data. No gastric mucosa-specific design elements can be found in the method itself, and claims such as ‘better represent the gastric mucosa’ are not supported experimentally or theoretically. This discrepancy cannot be resolved without reconstructing the entire paper or additional validation in the target domain, which is beyond the scope of what can be addressed in the rebuttal. In addition, no standard δ-threshold indicators have been reported in the field of endoscopic depth estimation, and the comparison with existing methods lacks completeness. For these reasons, we consider that the claims of the proposed method are not sufficiently validated and that it cannot be adopted.
- Reviewer confidence
Very confident (4)
- [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.
Reject
- [Post rebuttal] Please justify your final decision from above.
We commend the authors for reconstructing the clinical framing and stating that they are repositioning this study as a general stereo endoscopic reconstruction framework. On the other hand, this modification requires essential reorganisation across Abstract, Introduction, Methods and Conclusion, and is beyond the scope of what can be addressed at the camera-ready stage. Although the rebuttal may clarify the position of the paper, the initial clinical problem importance will be relatively weakened and, as a result, the importance of validation of the methodological contribution itself will increase. On this basis, the main concerns raised by Meta-Reviewers and multiple reviewers regarding methodological novelty and experimental validation (comprehensive ablation, teacher pseudo-labelling dependence, differentiation from existing methods, inadequate evaluation, etc.) are considered to be more important. The main concerns regarding methodological novelty and experimental validation (comprehensive ablation, teacher pseudo-labelling dependency, differentiation from existing methods, sufficiency of evaluation, etc.) remain unresolved. The main concerns have therefore not been sufficiently resolved by the rebuttal, and the original decision to reject is retained.
Author Feedback
We sincerely thank the Meta-Reviewer (MR) and Reviewers (R1–R4) for their time and expertise, and address the primary concerns below. 1.Methodological Contribution and Novelty [MR, R1, R2]
- Novel Synergy: Unlike existing transformer-based reconstruction methods, our framework jointly integrates a multi-scale backbone and row-wise attention to explicitly enforce horizontal epipolar constraints across different feature scales. This design enables effective feature alignment and direct 3D reconstruction under strong specular reflections and visually similar textures in endoscopic images, without explicitly estimating camera intrinsic parameters or poses. By suppressing attention in geometrically invalid regions, the proposed architecture provides a physically meaningful solution for robust stereo matching in challenging endoscopic scenarios.
- Beyond Compression: Our distillation-based strategy uses sparse but reliable teacher correspondences, enabling the student model through multi-scale interaction and row-wise attention to effectively learn geometry-aware stereo matching. Thus, the student model surpasses the teacher model and achieves more robust performance under challenging endoscopic conditions. 2.Clinical Framing and Validation Domain [MR, R4] We appreciate R4 and the MR’s concern regarding the discrepancy between our clinical motivation (gastroscopy) and validation (SCARED porcine abdominal anatomy).
- Gold-Standard Validation: The SCARED dataset is the gold-standard MICCAI challenge benchmark for “stereo correspondence and reconstruction of endoscopic data”. Validating on SCARED is a necessary step to demonstrate technical merit within the surgical vision community.
- Refinement of Claims: We acknowledge that our “gastric mucosa-specific” phrasing may be overly focused. Following R4’s suggestion, we will reframe the final manuscript as a general endoscopic stereo reconstruction framework, positioning “gastric diagnosis” as a primary future clinical application. 3.Experimental Setup and Training Pipeline [R1, R2, R4]
- Experimental Settings: In Table 1, for experimental fairness, the results for Endo-FASt3R and EndoSfM3D were directly adopted from their original papers, as both methods are designed for monocular temporal reconstruction rather than stereo-pair matching. Therefore, their evaluation results were only based on the left-view split of the SCARED dataset, and our comparisons follow the same protocol. Their performance would further degrade with stereo-pair training, because they rely on temporal reprojection optimization rather than stereo correspondence learning.
- Training Strategy: For DUSt3R and ESRT, both methods use the rectified stereo pairs officially provided by SCARED under the same train/test split, making the row-wise cross-attention assumption valid. DUSt3R requires GT pointmap supervision, while ESRT does not use any SCARED GT pointmap for training. Instead, ESRT uses a DUSt3R teacher pretrained on large-scale stereo datasets without exposure to SCARED, and only utilizes sparse reliable pseudo correspondences for distillation. The proposed multi-scale and geometric-constrained design then learns robust stereo matching for challenging endoscopic features without dense annotations. 4.Ablations and Efficiency Evaluation [R2, R3, R4]
- Ablation Studies: Table 1 provides an explicit ablation: ESRT-Full vs. ESRT-Row. The improvement in AbsRel from 0.053 to 0.048 directly quantifies the “remarkable effectiveness” of our row-wise constraint.
- Hardware and FPS: The 44 FPS were measured on an NVIDIA RTX 4090 GPU with batch size 1 and input resolution 320x256, consistent with the SCARED dataset setting used by the SOTA methods. 5.Quantitative Completeness: $\delta$ Metrics [R4]
- Prior Studies: As shown in the experiments in EndoSfM3D, which is superior to other SOTA methods, $\delta$ is also omitted due to limited space. We appreciate reviewers’ understanding.
Meta-Review
Meta-review #1
- Your recommendation
Invite for Rebuttal
- Please justify your decision. In case you deviate from the reviewers’ recommendations, explain in detail the reasons why. In case of an invitation for rebuttal, clarify which points are important to address in the rebuttal.
The reviewers commonly question the novelty and evidence behind the method, noting that it largely combines existing ideas—DUSt3R-style pointmap prediction, epipolar/row-wise matching, and standard teacher–student distillation—without clearly distinguishing itself from related stereo or endoscopic reconstruction methods, and without sufficient ablations to isolate the effects of distillation, row-wise attention, multi-scale fusion, losses, or backbone choices. They also raise concerns that the evaluation is incomplete and misaligned with the paper’s clinical claims, since experiments are limited to SCARED porcine cadaver data despite repeated gastroscopy/gastric-mucosa motivation, key baselines may not be evaluated under the same protocol, standard depth metrics are missing, and the dependence on teacher-generated pseudo labels is not adequately analyzed.
- After you have reviewed the rebuttal and updated reviews, please provide your recommendation based on all reviews and the authors’ rebuttal.
Accept
- Please justify your recommendation.
This paper has limitations on the experiments and evaluation: -Discrepancy between the clinical motivation (gastroscopy) and the validation (SCARED porcine abdominal anatomy). -Ablation study is limited.
However, the methodology has good novelty, and it is effective for the applications: -Row-wise cross-attention -Multi-scale backbone
This paper is expected to contribute to future advances in stereo reconstruction from endoscopic images, and I think it is acceptable.
Meta-review #2
- After you have reviewed the rebuttal and updated reviews, please provide your recommendation based on all reviews and the authors’ rebuttal.
Accept
- Please justify your recommendation.
The authors managed to provide convincing answers to the comments raised by the reviewers. The method is potentially impactful in the field of 3D reconstruction.
Meta-review #3
- After you have reviewed the rebuttal and updated reviews, please provide your recommendation based on all reviews and the authors’ rebuttal.
Reject
- Please justify your recommendation.
The paper addresses an important problem and reports promising efficiency and SCARED performance. The row-wise attention is reasonable, and the rebuttal clarifies the rectified-stereo setting and training without SCARED GT pointmaps.
However, the main concerns remain. The novelty is limited, as the method combines DUSt3R-style pointmap prediction, epipolar/row-wise matching, multi-scale features, and standard distillation. The experiments lack key ablations, matched baseline comparisons, teacher-dependence analysis, and standard depth metrics. The original gastroscopy/gastric-mucosa framing is also not supported by the SCARED-only validation and would require substantial reframing.
Overall, the work is promising but not sufficiently novel or validated for acceptance.