List of Papers Browse by Subject Areas Author List
Abstract
Reconstructing 4D (3D+t) cardiac geometry from sparse 2D echocardiography is highly desirable yet fundamentally challenged by geometric ambiguity and temporal discontinuity. To tackle these issues, we propose Echo4DIR, a novel test-time 4D implicit reconstruction framework.
Specifically, we learn robust 3D shape priors from statistical shape models (SSMs) via a cardiac conditional SDF, constructing an Epipolar Mask Encoder module with epipolar cross attention to effectively fuse multi-view features.
To bridge the synthetic-to-real domain gap, we introduce a self-supervised SDF-tailored differentiable rendering strategy for patient-specific 3D shape adaptation using uncalibrated clinical masks without requiring 3D ground truth.
Crucially, the inherent continuity of implicit representation overcomes sparse observations, enabling anatomically reliable geometry at arbitrary resolutions.
Furthermore, to empower our framework with physically continuous 4D extension, we introduce a Radial SDF Alignment strategy that strictly locks shape evolution to the predicted velocity field, fundamentally eliminating mesh drift.
Extensive experiments on synthetic benchmarks and real clinical datasets demonstrate that Echo4DIR achieves state-of-the-art 4D cardiac mesh reconstruction, notably yielding an impressive clinical overlap of up to 98.35\% Dice and 96.75\% IoU. The code will be available in https://github.com/ryannus2025-ai/Echo4DIR.
Links to Paper and Supplementary Materials
Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026/paper/3704_paper.pdf
SharedIt Link: Not yet available
SpringerLink (DOI): Not yet available
Supplementary Material: https://papers.miccai.org/miccai-2026/supp/3704_supp.zip
Link to the Code Repository
https://github.com/ryannus2025-ai/Echo4DIR
Link to the Dataset(s)
N/A
BibTex
@InProceedings{LiuYan_Echo4DIR_MICCAI2026,
author = { Liu, Yanan AND Li, Qinya AND Zhang, Hao AND He, Kangjian AND Yang, Xuan AND Li, Hao AND Xu, Dan AND Li, Lei},
title = { { Echo4DIR: 4D Implicit Heart Reconstruction from 2D Echocardiography Videos } },
booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026},
year = {2026},
publisher = {Springer Nature Switzerland},
volume = {LNCS 16889},
month = {September},
page = {pending}
}
Reviews
Review #1
- Please describe the contribution of the paper
This paper tackles the important problem of reconstructing 4D (3D+t) cardiac geometry from sparse 2D echocardiography. The paper introduces a novel test-time 4D implicit reconstruction framework and demonstrated improvements over prior methods on both synthetic and clinical images.
- Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
The paper is very well written, well motivated and included a comprehensive summary of prior work and challenges.
The paper introduced a few methodological innovations into the 4D cardiac anatomy reconstruction problem, including the addition of conditional SDFs regularized by SSM priors, DR to bridge the domain gap, and RSA to ensure temporal smoothness.
The paper demonstrated the advantages of each components with convincing metrics and appropriate statistics.
- Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.
The proposed method involves a SDF and test time optimization, both can be computationally expensive. A runtime analysis will be helpful to understand the computational cost of this approach.
The results would benefit from a more detailed analysis of regional accuracy, particularly in clinically important areas such as the mitral annulus and the aorta. Those regions are also important the digital twin implementation listed in the future work.
- Please rate the clarity and organization of this paper
Good
- Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.
The authors claimed to release the source code and/or dataset upon acceptance of the submission.
- Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?
N/A
- Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html
N/A
- Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.
(6) Strong Accept — must be accepted due to excellence
- Please justify your recommendation. What were the major factors that led you to your overall score for this paper?
This is an excellent paper that presents a novel method for addressing the important and clinically relevant problem of 4D cardiac anatomy reconstruction from echocardiography data. The methods are clearly described, and the contributions of individual components are well analyzed. The proposed approach demonstrates clear improvements over baseline methods.
- Reviewer confidence
Very confident (4)
- [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.
N/A
- [Post rebuttal] Please justify your final decision from above.
N/A
Review #2
- Please describe the contribution of the paper
1.A Novel 4D Implicit Reconstruction Framework (Echo4DIR): The authors propose a pioneering test-time optimization (TTO) framework that reconstructs 3D+t (4D) cardiac geometry from sparse 2D echocardiography. 2.Epipolar Mask Encoder with Cross Attention: To effectively extract and fuse features from multi-view 2D echo masks, they construct an Epipolar Mask Encoder module integrated with Epipolar Cross Attention (ECA). This helps the network learn robust 3D shape priors from statistical shape models (SSMs). 3.Self-Supervised SDF-Tailored Differentiable Rendering: To bridge the domain gap between synthetic SSM training data and real-world clinical data, the authors introduce a differentiable rendering strategy tailored for SDFs. This allows for patient-specific 3D shape adaptation using uncalibrated real clinical masks without requiring any 3D ground truth.
- Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
1.The framework demonstrates a significant quantitative leap in performance on the synthetic SSM dataset. Echo4DIR substantially outperforms the latest baselines (such as the mesh-based MIA’25). 2.The experimental design is exceptionally thorough, validating the framework across two distinct domains. The authors utilize a 10k-mesh synthetic dataset to rigorously assess 3D geometric precision against a strict ground truth, while concurrently evaluating a 144-subject real clinical dataset to prove practical clinical utility.
- Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.
1.The framework’s evaluation on the real-world clinical dataset (the Control Cohort) relies entirely on 2D projection overlap metrics, specifically 2D Dice and IoU. However, 2D projection overlap does not equate to 3D geometric accuracy, particularly in the “blind spots” between the sparse ultrasound probe views. Without evaluating the method against paired 3D clinical ground truth (such as corresponding patient-specific Cardiac CT or MRI scans), it is impossible to definitively prove that the method does not suffer from anatomical hallucinations in unobserved regions. 2.The assumption of a purely rigid, affine transformation to map the 2D image plane to the 3D spatial coordinates ignores non-linear distortions, beam thickness artifacts, and refraction that occur when sound waves pass through varying tissue densities. This simplified probe model may limit the ultimate precision of the spatial mapping in highly complex clinical cases
- Please rate the clarity and organization of this paper
Good
- Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.
The authors claimed to release the source code and/or dataset upon acceptance of the submission.
- Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?
N/A
- Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html
N/A
- Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.
(4) Weak Accept — marginally above the acceptance threshold, but would not mind if rejected, dependent on rebuttal
- Please justify your recommendation. What were the major factors that led you to your overall score for this paper?
See the strengths and weakness.
- Reviewer confidence
Confident but not absolutely certain (3)
- [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.
N/A
- [Post rebuttal] Please justify your final decision from above.
N/A
Review #3
- Please describe the contribution of the paper
The paper proposes Echo4DIR, a test-time 4D implicit reconstruction framework that recovers patient-specific cardiac geometry from sparse multi-view 2D echocardiography by combining SSM-based shape priors, conditional SDFs, and differentiable rendering.
- Please list the major strengths of the paper: you should highlight a novel formulation, an original way to use data, demonstration of clinical feasibility, a novel application, a particularly strong evaluation, or anything else that is a strong aspect of this work. Please provide details, for instance, if a method is novel, explain what aspect is novel and why this is interesting.
1.The paper addresses a clinically meaningful problem: reconstructing patient-specific 4D cardiac geometry from sparse multi-view 2D echocardiography. This is an existing task. 2.The method is technically coherent, combining SSM priors, conditional SDFs, differentiable rendering, and temporal modeling, with solid quantitative results and ablations.
- Please list the major weaknesses of the paper. Please provide details: for instance, if you state that a formulation, way of using data, demonstration of clinical feasibility, or application is not novel, then you must provide specific references to prior work.
1.The real-data validation is still indirect, since the main clinical evaluation is based on 2D projection overlap rather than true 3D/4D ground truth. 2.The paper’s framing is somewhat broader than its actual setting, as the experiments focus on LV reconstruction from segmented masks rather than full-heart reconstruction directly from raw echo videos.
- Please rate the clarity and organization of this paper
Satisfactory
- Please comment on the reproducibility of the paper. Please be aware that providing code and data is a plus, but not a requirement for acceptance.
The authors claimed to release the source code and/or dataset upon acceptance of the submission.
- Based on your review and your understanding of the MICCAI Scientific Code of Ethics, do you believe this submission may involve a potential ethics concern or violation?
N/A
- Optional: If you have any additional comments to share with the authors, please provide them here. Please also refer to our Reviewer’s guide on what makes a good review and pay specific attention to the different assessment criteria for the different paper categories: https://conferences.miccai.org/2026/en/REVIEWER-GUIDELINES.html
N/A
- Rate the paper on a scale of 1-6, 6 being the strongest (6-4: accept; 3-1: reject). Please use the entire range of the distribution. Spreading the score helps create a distribution for decision-making.
(4) Weak Accept — marginally above the acceptance threshold, but would not mind if rejected, dependent on rebuttal
- Please justify your recommendation. What were the major factors that led you to your overall score for this paper?
The paper addresses a clinically meaningful problem and presents a framework with solid empirical results. My recommendation is mainly based on the overall completeness of the method and experiments, while I also note that the clinical validation is still indirect and the methodological novelty appears moderate rather than highly substantial.
- Reviewer confidence
Not confident (1)
- [Post rebuttal] After reading the authors’ rebuttal, please state your final opinion of the paper.
N/A
- [Post rebuttal] Please justify your final decision from above.
N/A
Author Feedback
N/A
Meta-Review
Meta-review #1
- Your recommendation
Provisional Accept
- Please justify your decision. In case you deviate from the reviewers’ recommendations, explain in detail the reasons why. In case of an invitation for rebuttal, clarify which points are important to address in the rebuttal.
All reviewers appreciated this paper’s methodological novelty and completeness of experimental comparisons. This paper received 4, 4, 6 scores, which guarantees an early accept. The authors are encouraged to further polish their paper based on the reviewers’ comments.