Abstract

Radiomic analysis of multi-centre fluorine-18 fluorodeoxyglucose positron emission tomography / computed tomography (PET-CT) is increasingly used to identify standardized uptake value (SUV)-based biomarkers, but acquisition-level reliability is poorly captured by standard harmonization frameworks. We propose a metadata-driven quality control (QC) pipeline that assigns interpretable per-scan confidence tiers along two axes: SUV timing confidence, and PET–CT spatial agreement. The tiers are deterministic, rule-based categories derived from pre-specified thresholds, not calibrated probabilistic uncertainty estimates. Applied to 130 esophageal cancer patients from four Dutch centres, the pipeline flagged 40% of scans (WARN or FAIL), with the two tiers triggered by distinct conditions (spatial failures vs SUV-quantification deviations). SUV harmonization differed from an independent reference by a median of 1.3% at the liver region across 127 paired scans (intraclass correlation coefficient 0.78, 95% CI 0.47–0.94). Excluding lower-confidence scans yielded apparent improvements in radiomic feature stability and pathological complete response prediction, but two matched-random controls showed these gains were largely attributable to centre and vendor composition rather than QC filtering. The pipeline contribution is independent of these downstream findings; confirming a genuine downstream effect will require larger, centre-stratified cohorts. Tier assignment was also sensitive to the liver SUV window, which acted as the dominant criterion; the spatial thresholds were comparatively inert.

Links to Paper and Supplementary Materials

Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026-sat/paper/UNSURE2026_046.pdf

SharedIt Link: Not yet available

SpringerLink (DOI): Not yet available

Supplementary Material: https://papers.miccai.org/miccai-2026-sat/supp/UNSURE2026_046_supp.pdf

Link to Open Review

Open Review Page: https://openreview.net/profile?id=~Marta_V._Araújo1

BibTex

@InProceedings{AraMar_ConfidenceTiered_MICCAISAT2026,
        author = { Araújo, Marta V. AND Moos, Shira AND Boellaard, Ronald AND Marquering, Henk A. AND Bereska, Jacqueline I. AND Gisbertz, Suzanne S.},
        title = { { Confidence-Tiered Quality Control for Reliable Radiomic Biomarkers in Multicentre PET-CT } },
        booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026 Workshops and Challenges},
        year = {2026},
        publisher = {Springer Nature Switzerland},
        volume = {LNCS 17260},
        month = {pending},
        page = {pending}
}


back to top