Abstract

Automated segmentation increasingly supplies the tumor measurements that drive post-treatment glioma surveillance, yet aggregate accuracy has saturated across architectures, leaving reliability, not accuracy, as the axis that decides whether a clinician can trust a given output. Studying the publicly released checkpoints of the BraTS 2024 winning ensemble (a canonical CNN, a modern CNN, and a transformer) on a temporally separated, label-complete held-out set with patient-level bootstrap confidence intervals, we show this reliability is spatially structured: boundary calibration error exceeds interior calibration error by 3.4–8.3-fold (cross-architecture ensemble) and is worst at the resectioncavity rim, the site that drives the progression-versus-treatment-effect decision. Most of a single model’s cavity calibration deficit is recoverable without retraining (a two-parameter interior/boundary temperature improves Brier and NLL significantly over the native model and beats a global scalar), but recalibration is monotone: it corrects the probabilities while leaving the thresholded measurement and any triage on the raw uncertainty unchanged, so safe deployment needs region-awareness in two distinct places. Our central result concerns the second: under distribution-free risk control, a whole-case uncertainty score certifies no usable cavity operating point (risk–coverage area above the keep-all cavity segmentation error for all three architectures), whereas a region-aware score certifies a guaranteed operating point with bounded mean cavity segmentation error, retaining 53–68% of cases at risk ≤ 0.25, that transfers to held-out patients, with the smallest cavities remaining the hard cases, which the method flags for human review rather than ranking by confidence. The takeaway is operational: measure uncertainty where the high-stakes decision is actually made (here, the resection cavity) and treat recalibration and triage as two separate region-aware steps.

Links to Paper and Supplementary Materials

Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026-sat/paper/UNSURE2026_008.pdf

SharedIt Link: Not yet available

SpringerLink (DOI): Not yet available

Supplementary Material: https://papers.miccai.org/miccai-2026-sat/supp/UNSURE2026_008_supp.pdf

Link to Open Review

Open Review Page: https://openreview.net/profile?id=~Mostafa_Abdalla_Mostafa_Badr1

BibTex

@InProceedings{BadMos_Reliability_MICCAISAT2026,
        author = { Badr, Mostafa Abdalla Mostafa AND Ibrahim, Abdelhadi Nabih Ahmed AND El-Khoribi, Reda Abdelwahab Ahmed},
        title = { { Reliability, Not Accuracy, Is the Bottleneck in AI-assisted Post-Treatment Glioma Segmentation: Region-Aware Recalibration and Risk-Controlled Triage } },
        booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026 Workshops and Challenges},
        year = {2026},
        publisher = {Springer Nature Switzerland},
        volume = {LNCS 17260},
        month = {pending},
        page = {pending}
}


back to top