Abstract
The MVAA 2026 challenge poses complementary mitral valve segmentation tasks across 3D transesophageal echocardiography (TEE) and 2D intraoperative surgical video, spanning different data regimes, dimensionalities and inductive biases. We report our submissions to Task 2 and Task 3. For \textbf{Task 1} (3D cardiac CT, 27 labelled volumes and approximately 1{,}040 unlabelled volumes), we develop a physically consistent residual-encoder nnU-Net pipeline with foreground-enriched sampling, selective pseudo-label self-training, and validation-driven connected-component postprocessing. A 5-fold ensemble reaches a mean DSC of 0.839, an average surface distance of 0.71,mm, and an HD95 of 3.8,mm, while conservative small-component removal primarily reduces extreme Hausdorff errors with negligible effect on overlap. For \textbf{Task 2} (3D TEE, 105 training volumes), we systematically explored architectural ensembling and label-formulation diversity within the nnU-Net v2 framework. Our final submission is a dual-architecture ensemble (standard nnU-Net plus Residual-Encoder-M) trained with 5-fold cross-validation, reaching a mean per-class DSC of 0.8451 with keep-largest-connected-component postprocessing, a reproducible $+0.004$ DSC gain over single-architecture ensembling. For \textbf{Task 3} (2D surgical video, 118 valve-present labelled frames and 1{,}379 unlabelled frames), we build on the official baseline framework (UNet++ with Mean~Teacher semi-supervised learning), enhanced with an ImageNet-pretrained EfficientNet-B5 encoder and a leave-one-recording-out cross-validation scheme that respects the video-grouped structure of the data. This reaches a 3-fold composite of 0.557, with the best fold matching the published leaderboard anchor (0.590). We additionally document a systematic negative result: label-shape priors (region-based training with an auxiliary valve-envelope head, and five union-guided postprocessing variants) yield a strong auxiliary union predictor (0.89 Dice) that nonetheless fails to transfer into per-class Dice gains, clarifying when auxiliary label-shape supervision does and does not pay.
Links to Paper and Supplementary Materials
Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026-sat/paper/MVAA_103.pdf
SharedIt Link: Not yet available
SpringerLink (DOI): Not yet available
Supplementary Material: Not Submitted
Link to Open Review
Open Review Page: https://openreview.net/forum?id=k7C42ulZZA
BibTex
@InProceedings{GonJes_Formulation_MICCAISAT2026,
author = { Gonzalez Riveros, Jesus David AND Rengifo, Juan Pablo Betancur},
title = { { Formulation Diversity and Boundary-Aware Postprocessing for Mitral Valve Segmentation in 3D TEE and 2D Surgical Video } },
booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026 Workshops and Challenges},
year = {2026},
publisher = {Springer Nature Switzerland},
volume = {LNCS 17268},
month = {pending},
page = {pending}
}