Frozen hematology foundation-model (FM) embeddings reach near-saturated in-domain white-blood-cell (WBC) accuracy, but clinical deployment demands reliability across scanners, sites, stains and preparation pipelines. We audit 15 frozen encoders (hematology, pathology, and general vision encoders) across four public single-cell acquisition domains along two axes: accuracy robustness and calibration. In-domain linear-probe macro-F1 is saturated (0.98–0.997), yet cross-dataset macro-F1 drops 34–72% and rankings re-order: DinoBloom-L, the in-domain best, falls to 10th of 15 on the most-shifted target (MLL23) at the benchmark’s shared 224-px input, while RedDino and several general and pathology encoders outrank it. Rank transfer is probe-dependent: 1-NN retrieval is more stable on average than a source-fitted linear head (median ρ 0.65 vs 0.45), but neither clean-domain probe universally predicts target robustness. Calibration also collapses: source-trained probes are nearly calibrated in-domain (Expected Calibration Error [ECE] 0.004) but become confidently wrong off-domain (ECE 0.35), and source-fitted temperature scaling transfers poorly. We further audit pretraining exposure and identify MLL23 as corresponding to DinoBloom’s internal cohort; because the only DinoBloom-held-out dataset is also our source domain, this benchmark cannot isolate exposure from scanner-associated distribution shift. Finally, label-free adaptation and marginal-entropy-based model selection appear safe under balanced evaluation but fail under realistic WBC class-prior shift. Class-Balanced Re-standardization (CBR), a training-free pseudo-label-balanced feature normalization, improves all evaluated target-prior scenario means and partially improves calibration, although encoder-level exceptions and residual miscalibration remain. These results argue that hematology FM benchmarks must jointly audit accuracy, calibration, exposure, and class-prior robustness.
Links to Paper and Supplementary Materials
Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026-sat/paper/HemaRAI_001.pdf
SharedIt Link: Not yet available
SpringerLink (DOI): Not yet available
Supplementary Material: https://papers.miccai.org/miccai-2026-sat/supp/HemaRAI_001_supp.pdf
Link to Open Review
Open Review Page: https://openreview.net/forum?id=DusvF1i1BF
BibTex
@InProceedings{ShaJai_Can_MICCAISAT2026,
author = { Sharma, Jai Kumar AND Tapadiya, Peeyush},
title = { { Can You Trust Frozen Hematology Foundation Models under Acquisition Shift? } },
booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026 Workshops and Challenges},
year = {2026},
publisher = {Springer Nature Switzerland},
volume = {LNCS 17252},
month = {pending},
page = {pending}
}