Abstract
The EchoRisk 2026 challenge defines three tasks on apical
echocardiography video from a cardio-oncology cohort: left-ventricular
(LV) ejection fraction (EF) regression (Task 1), dysfunction classifica-
tion defined by global longitudinal strain (Task 2), and prediction of early
cardiotoxicity from a single pre-treatment scan (Task 3), each scored per
examination. We use self-supervised video encoders as frozen feature ex-
tractors and train an attentive-pooling probe on top. Under one protocol,
we compare general-purpose and echo-pretrained encoders. On Task 1,
adding public EchoNet-Dynamic EF labels to the probe’s training data
reduces the mean absolute error (MAE) of a general video encoder from
4.91 to 4.56, matching an echo-pretrained encoder and improving on
the organisers’ supervised baseline of 5.02. Fine-tuning the encoder does
not improve on the frozen probe at this label scale. Content hashing
also revealed repeated cines across released training and validation keys,
sometimes with conflicting labels; we remove these records before all re-
ported experiments. Quantitative results are reported for Task 1 only,
on the validation split that was also used for model selection, and may
therefore be optimistic; we make no hidden-test claim.
Links to Paper and Supplementary Materials
Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026-sat/paper/EchoRisk2026_021.pdf
SharedIt Link: Not yet available
SpringerLink (DOI): Not yet available
Supplementary Material: Not Submitted
Link to Open Review
Open Review Page: https://openreview.net/forum?id=7FYoa8czNL
BibTex
@InProceedings{BidRen_General_MICCAISAT2026,
author = { Bidart, Rene AND Ghosh, Shrimanti},
title = { { General vs. Echo-Specific Video Foundation Models for Echocardiographic Risk } },
booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026 Workshops and Challenges},
year = {2026},
publisher = {Springer Nature Switzerland},
volume = {LNCS 17268},
month = {pending},
page = {pending}
}