Abstract

Foundation models have recently demonstrated strong capabilities across a wide range of medical imaging tasks. However, their performance in structured clinical interpretation settings remains insufficiently explored. In lung cancer screening, interpretative variability persists despite standardized frameworks such as Lung-RADS. In this study, we evaluate MedGemma, a medical general-purpose foundation model derived from Gemini and its fine-tuned version adapted for lung cancer detection and diagnosis, compared against radiologists performing Lung-RADS® v2022 assessment on the NLST dataset. Twelve radiologists independently evaluated each case in a multi-reader design, enabling quantification of inter-reader variability. Radiologists achieved a mean AUC of 0.90, with substantial variability across readers (range: 0.80–0.94). The native foundation model achieved an AUC of 0.70, failing to reach clinically relevant performance. In contrast, fine-tuning significantly improved performance to an AUC of 0.83, placing the model within the lower range of individual radiologists performance. These findings highlight a trade-off between peak accuracy and prediction consistency. Unlike radiologists, under fixed conditions, the model produces deterministic outputs, removing inter-run variability under identical inputs, in contrast to inter-reader variability observed among radiologists. This supports the role of fine-tuned foundation models potential complementary tools for clinical decision support, particularly in settings with limited expertise. However, evaluation is performed on a case-enriched cohort from NLST and does not account for real-world prevalence or external validation, limiting direct clinical generalization.

Links to Paper and Supplementary Materials

Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026-sat/paper/CaPTion_008.pdf

SharedIt Link: Not yet available

SpringerLink (DOI): Not yet available

Supplementary Material: Not Submitted

Link to Open Review

Open Review Page: https://openreview.net/profile?id=~Benjamin_Renoust1

BibTex

@InProceedings{RenBen_Performance_MICCAISAT2026,
        author = { Renoust, Benjamin AND Baudot, Pierre AND Foriel, Tiffany AND Haddou, Yousra AND Voyton, Charles AND Siot, Pierre-Henri AND Geremia, Ezequiel AND Francis, Danny AND Brisset, Jean-Christophe AND Bourdès, Valérie AND Bodard, Sylvain AND Huet, Benoit},
        title = { { Performance vs Consistency: Evaluating a Foundation Model in Lung-RADS Screening } },
        booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026 Workshops and Challenges},
        year = {2026},
        publisher = {Springer Nature Switzerland},
        volume = {LNCS 17278},
        month = {pending},
        page = {pending}
}


back to top