Abstract
Deep learning-based super-resolution (SR) usually does not
perform well across domains, e.g., different magnetic resonance imaging
(MRI) datasets, usually due to two reasons: 1) there is often a mismatch
in terms of data distributions between the training data and test data,
and 2) the overly simplified image degradation models in popular SR
techniques do not model the underlying physical processes well. Hence,
SR models often require extensive supervised fine-tuning when transferring
to new datasets (target domains). In this paper we propose UTAR,
a physics-informed Unsupervised Test-time domain Adaptation framework
for deep learning-based super-resolution for magnetic Resonance
imaging. UTAR adapts a pre-trained source-domain SR model to a new
target domain (e.g., images from a new hospital) using low-resolution
(LR) target-domain images only. This is possible through a new physicsinspired
imaging chain degradation model (PIC), which incorporates
both spatial and frequency domain (k-space) degradation. Such dualdomain
degradation modeling enables us to better capture the variations
of LR images that could potentially affect a model’s performance
across different unseen MRI domains. We further propose a conditional
consistency learning (CCL) strategy to encourage prediction consistency,
serving as the supervision signal for TTA. Our method is generic and can
accommodate arbitrary pre-trained SR networks. Experimental results
verify the effectiveness of UTAR in reducing the performance gap with
minimum efforts. UTAR outperforms earlier methods based on different
degradation-based strategies and existing test time adaptation (TTA)
approaches. We expect our method to provide a key step towards the
deployment of MRI SR algorithms in clinical applications where significant
domain shifts are inevitable.
Links to Paper and Supplementary Materials
Main Paper (Open Access Version): https://papers.miccai.org/miccai-2026-sat/paper/ADSMI2024_001.pdf
SharedIt Link: Not yet available
SpringerLink (DOI): Not yet available
Supplementary Material: Not Submitted
Link to Open Review
Open Review Page: Not Available
BibTex
@InProceedings{ZhaWei_Physicsinformed_MICCAISAT2026,
author = { Zhang, Weitong AND Stelter, Jonathan AND Li, Liu AND Kori, Avinash AND Ouyang, Cheng AND Chen, Chen AND Knoll, Florian AND Karampinos, Dimitrios AND Kainz, Bernhard},
title = { { Physics-informed Unsupervised Test-time Adaptation for MRI Super-Resolution } },
booktitle = {Medical Image Computing and Computer Assisted Intervention -- MICCAI 2026 Workshops and Challenges},
year = {2026},
publisher = {Springer Nature Switzerland},
volume = {LNCS 17276},
month = {pending},
page = {pending}
}